7-28
(TROUBLE 6) Convection oven does not operate at all or convection cook is bad.
CONDITION
CHECK
RESULT
CAUSE
REMEDY
Convection indicator
light but oven does
not go into cook cycle
when START/ENTER
pad is touched.
Abnormal.
Normal.
No continuity.
Check the
connection between
P.C.B. assembly and
headwire connector.
Defective Relay
10.
Replace Relay
10.
Loose connection.
Connect them
tightly.
Check the Relay
10 of P.C.B.
assembly.
Temperature in
the oven cavity is
lower or higher
than preset.
Abnormal.
Normal.
Abnormal.
Check the
convection heater
element.
Defective Relay
10.
Replace
Relay 10.
Defective
convection heater.
Replace
convection heater.
Check the Relay
10 of P.C.B.
assembly.
Abnormal.
Check the
circulation motor.
Defective
circulation motor.
Replace
circulation motor.
Cook on the
glass tray.
Check the Rack.
Without
metal rack.
Cook with
metal rack.
Error message
shows in the display.
Check the
thermistor.
Thermistor open
or short.
Replace
thermistor.
Normal.
Normal.
Normal.