EN
CRP40
Troubleshooting
21
10
Troubleshooting
Compressor does not run
Fault
Possible cause
Remedy
U
TERM
= 0 V
There is an interruption in the
connection between the battery and
the electronics.
Establish a connection.
Main switch faulty (if installed).
Replace the main switch.
Additional supply line fuse has blown
(if installed).
Replace the supply line
fuse.
U
TERM
U
ON
Battery voltage is too low.
Charge the battery.
Start attempt with
U
TERM
U
OFF
Loose cables.
Poor contact (corrosion).
Establish a connection.
Battery capacity too low.
Replacing the battery.
Cable cross section too small.
Replace the cable
(fig.
Start attempt with
U
TERM
U
ON
Ambient temperature too high.
–
Insufficient ventilation and/or air
supply.
Move the refrigerator to
another location.
Condenser is dirty.
Clean the condenser.
Fan defective (if installed).
Replace the fan.
Electric circuit between
the pins in the compres-
sor interrupted
Defective compressor.
Replace the compressor.
Usage when the
ambient temperature is
too low
The compressor only starts up at an
ambient temperature of more than
+16 °C.
Only switch on the refrig-
erator at an ambient tem-
perature of more than
+16 °C.
U
TERM
Voltage between the positive and negative terminals of the electronics
U
ON
Cut-in voltage of the electronics
U
OFF
Cut-off voltage of the electronics
Содержание CoolMatic CRP 40S
Страница 3: ...CRP40 3 380 545 182 53 310 200 132 536 23 1 2...
Страница 4: ...CRP40 4 0 1 3 2 4 3 1 ca 50 mm 4...
Страница 5: ...CRP40 5 5 1 Vent Lock 1 6...
Страница 6: ...CRP40 6 8 7 mm l m 12V 24V 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 0 2 6 10 14 9...
Страница 7: ...CRP40 7 bn bn bu bu 4 1 2 3 0 1 rd bk a...
Страница 79: ......