EN
CK500
Installing the device
13
6
Installing the device
!
A
I
6.1
Notes on the installation position
•
It is best to install the extractor hood in the middle of the cooking area and
integrate it into a wall-mounted cupboard, where possible.
•
The distance between the gas hob flame and the extractor hood must be at least
50 cm.
•
The outlet air can be discharged upwards or to the side.
If the outlet air is to be discharged to the side, an additional fan (not included)
must be used.
•
Prior to installation it must be clarified how the air outlet hose will be installed and
where the mushroom vent can be installed (fig.
4
, page 4).
When doing so, note any cupboard dividing walls and shelves.
The holes for the air outlet hose must be positioned so that no electrical cables in
the structure, no supporting structures or vehicle parts, such as roof racks, are
affected.
WARNING!
The distance between the gas hob flame and the extractor hood must
be at least 50 cm.
NOTICE!
Make sure when you are planning the location of the air outlet guide that
there are no electrical cables or vehicle parts in the vicinity, such as a roof
rack. Otherwise they might be damaged when drilling.
NOTE
•
This section describes how to discharge the outlet air upwards.
•
The outlet air can also be discharged to the side. Additional
accessories are necessary to do this. In this case have the extractor
hood installed at an authorised workshop.
CK500-IO-16s-.book Seite 13 Donnerstag, 1. Dezember 2016 11:22 11
Содержание CK500
Страница 2: ......
Страница 3: ...CK500 3 1 2 3 4 5 6 1 1 2 3 4 5 6 7 2 2 1 3 ...
Страница 4: ...CK500 4 1 4 A B 5 ...
Страница 5: ...CK500 5 234 5 189 5 6 2 1 7 ...
Страница 6: ...CK500 6 8 Ø 75 80 ø 1 1 0 1 2 9 ...
Страница 7: ...CK500 7 1 2 0 a ...
Страница 183: ......