CDF26: Setting the battery monitor mode

This is how to select the battery monitor mode:

Switch on the cooler.

Press the “SET” button three times.

Use the “+” and “–” buttons to select the battery monitor mode.

The selected mode then appears in the display for a few seconds. The  display 
flashes several times before it returns to the current temperature.

CDF36, CDF46: Setting the battery monitor mode

This is how to select the battery monitor mode:

Switch on the cooler.

Press the “SET” button three times.

Use the “ADJUST” button to select the battery monitor mode.

7.5

Using the cooler

A

Place the cooler on a firm foundation. 
Make sure that the ventilation slots are not covered and that the heated air can 
dissipate.

Close the cooler, see chapter “Connecting the cooler” on page 12.

A

Locking the cooler

Close the lid.

Press the lock (fig.

6

1, page 3) down, until it latches in place audibly.

NOTICE! Danger of overheating!

Ensure at all times that there is sufficient ventilation so that the heat that 
generated during operation can dissipate. Ensure that the ventilation 
slots are not covered. Make sure that the device is sufficiently far away 
from walls and other objects so that the air can circulate.

NOTICE! Danger from excessively low temperature!

Ensure that the only those objects are placed in the cooler that are 
intended to be cooled at the selected temperature.

CDF18-26-36-46--O-16s.book  Seite 14  Montag, 7. November 2016  2:13 14

Autogoods “130”

130.com.ua

Содержание CDF 36

Страница 1: ...ries SECURITY SYSTEMS Car alarms Bike alarms Mechanical blockers Immobilizers Sensors Accessories OPTIC AND LIGHT Xenon Bixenon Lamps LED Stroboscopes Optic and Headlights Washers Light rain sensors A...

Страница 2: ...CDF18 CDF26 CDF36 CDF46 Compressor Cooler Operating manual 4 EN COOLING BOXES COOLFREEZE CDF18 26 36 46 O 16s book Seite 1 Montag 7 November 2016 2 13 14 Autogoods 130 1 3 0 c o m u a...

Страница 3: ...FREEZE ERROR POWER HIGH 0 LOW TEMPERATURE BATTERY MONITOR 1 CDF18 2 3 4 5 2 12 24V DC CDF26 CDF36 CDF46 3 ERROR POWER CDF26 1 3 4 5 6 7 2 4 CDF18 26 36 46 O 16s book Seite 2 Montag 7 November 2016 2 1...

Страница 4: ...CoolFreeze 3 ERROR POWER CDF36 CDF46 1 3 4 5 6 2 5 1 6 1 2 3 4 5 6 7 CDF26 CDF36 CDF46 1 2 8 CDF18 26 36 46 O 16s book Seite 3 Montag 7 November 2016 2 13 14 Autogoods 130 1 3 0 c o m u a...

Страница 5: ...anufacturer cannot be held liable for damage resulting from improper usage or incorrect operation Contents 1 Explanation of symbols 5 2 Safety instructions 5 3 Scope of delivery 7 4 Accessories 7 5 In...

Страница 6: ...ory or mental capacities or a lack of experience and or knowledge providing they are supervised or have been taught how to use the device safely and are aware of the resulting risks Cleaning and user...

Страница 7: ...he socket by the cable Disconnect the cooler and other power consuming devices from the battery before connecting the quick charging device Disconnect the cooler or switch it off when you turn off the...

Страница 8: ...t covered Do not fill the inner container with ice or fluid Never immerse the device in water Protect the device and the cable against heat and moisture 3 Scope of delivery fig 1 page 2 shows the scop...

Страница 9: ...ree insulation and powerful compressor ensure especially fast cooling The cooler is designed for mobile use When used on boats the cooler can be withstand a constant heel inclination of 30 An integrat...

Страница 10: ...Device is switched on and ready for operation LED is lit yellow Set temperature has been reached 3 ERROR LED flashes red Switched on device is not ready for operation 4 BATTERY MONITOR Switch on devic...

Страница 11: ...Display switched off auto matically due to low battery voltage 3 ERROR LED flashes red Device is switched on but not ready for operation 4 SET Selects the input mode Temperature setting Celsius or Fah...

Страница 12: ...ange Display switched off automatically due to low battery voltage 3 ERROR LED flashes red Device is switched on but not ready for operation 4 SET Selects the input mode Temperature setting Celsius or...

Страница 13: ...ed with an electronic system to prevent the polarityreversal Thisprotectsthecooleragainstshort circuitingwhenconnectingto a battery Plug the 12 24 V connection cable fig 1 2 page 2 into the DC voltage...

Страница 14: ...battery is recharged Battery monitor mode LOW HIGH Switch off voltage at 12 V 10 2 V 0 3 V 11 2 V 0 3 V Restart voltage at 12 V 11 2 V 0 3 V 12 2 V 0 3 V Switch off voltage at 24 V 22 0 V 0 3 V 23 9...

Страница 15: ...Make sure that the ventilation slots are not covered and that the heated air can dissipate Close the cooler see chapter Connecting the cooler on page 12 A Locking the cooler Close the lid Press the l...

Страница 16: ...lit green The display switches on and shows the current cooling temperature The cooler starts cooling the interior CDF18 Switching off the cooler Empty the cooler To Switch the cooler off Slide the sl...

Страница 17: ...erature 7 7 Selecting the temperature unit CDF26 You can switch the temperature display between Celsius and Fahrenheit To do this proceed as follows Switch on the cooler Press the SET button twice Use...

Страница 18: ...ut of the upper half of the housing fig 7 1 page 3 Carefully raise the upper half of the housing from the lower fig 7 6 page 3 half Take out the contact pin fig 7 3 page 3 Replace the defective fuse f...

Страница 19: ...back of the instruction manual for the addresses or your retailer For repair and guarantee processing please include the following documents when you send in the device A copy of the receipt with pur...

Страница 20: ...ool plug is inserted ERROR LED flashes Battery voltage is too low Test the battery and charge it as needed When operating from the DC power socket The ignition is on and the device is not work ing and...

Страница 21: ...Rated current 12 Vg 3 5 A 5 0 A 24 Vg 1 9 A 2 5 A Cooling capacity 10 C to 18 C Climate class N or T Ambient temperature 16 C 43 C Dimensions WxHxD in mm 465 x 414 x 300 550 x 425 x 260 Weight 9 5 kg...

Страница 22: ...24 Vg 2 5 A 2 5 A Cooling capacity 10 C to 15 C Climate class N or T Ambient temperature 16 C 43 C Dimensions WxHxD in mm 560 x 380 x 340 560 x 475 x 340 Weight 12 5 kg 13 7 kg Tests Certification NO...

Отзывы:

Похожие инструкции для CDF 36