CDF26: Setting the battery monitor mode
This is how to select the battery monitor mode:
1. Switch on the cooler.
2. Press the “SET” button three times.
3. Use the “+” and “–” buttons to select the battery monitor mode.
✔
The selected mode then appears in the display for a few seconds. The display
flashes several times before it returns to the current temperature.
CDF36, CDF46: Setting the battery monitor mode
This is how to select the battery monitor mode:
1. Switch on the cooler.
Battery monitor mode
LOW
HIGH
Switch-off voltage at 12 V
10.2 V ± 0.3 V
11.2 V ± 0.3 V
Restart voltage at 12 V
11.2 V ± 0.3 V
12.2 V ± 0.3 V
Switch-off voltage at 24 V
22.0 V ± 0.3 V
23.9 V ± 0.3 V
Restart voltage at 24 V
23.3 V ± 0.3 V
25.1 V ± 0.3 V
Battery monitor mode
LOW
MED
HIGH
Switch-off voltage at 12 V
10.1 V 11.4 V 11.8 V
Restart voltage at 12 V
11.1 V 12.2 V 12.6 V
Switch-off voltage at 24 V
21.5 V 24.1 V 24.6 V
Restart voltage at 24 V
23.0 V 25.3 V 26.2 V
NOTE
When the cooler is supplied by the starter battery, select the battery
monitor mode “HIGH”. If the cooler is connected to a supply battery,
the battery monitor mode “LOW” will suffice.
If you wish to operate the cooler from the AC mains, set the battery
monitor to the “LOW” position.
DometicCDF18-26-36-46_OPM_4445102393_EMEA16_20xx-xx-xx.book Seite 14 Mittwoch, 22. Dezember 2021 2:24 14
Содержание CDF 26
Страница 205: ...RU CDF 205 3 8 A DometicCDF18 26 36 46_OPM_4445102393_EMEA16_20xx xx xx book Seite 205 Mittwoch 22 Dezember 2021 2 24 14...
Страница 206: ...RU CDF 206 50 DometicCDF18 26 36 46_OPM_4445102393_EMEA16_20xx xx xx book Seite 206 Mittwoch 22 Dezember 2021 2 24 14...
Страница 295: ...DometicCDF18 26 36 46_OPM_4445102393_EMEA16_20xx xx xx book Seite 295 Mittwoch 22 Dezember 2021 2 24 14...