Dometic CA2500
Troubleshooting
35
➤
Clean the remote control with a slightly damp cloth from time to time. We
recommend using a cleaning cloth for glasses to clean the display.
10
Troubleshooting
Possible
malfunction
Cause
Remedial measure
Device con-
stantly switches
itself off.
Icing sensor has tripped.
Outer temperature is too low or all
air nozzles are closed.
No cooling
capacity
The device is not set to cooling.
➤
Set the device to cooling.
The ambient temperature is above
43 °C.
The roof air conditioner is only
designed for ambient temperatures
of up to 43 °C.
The temperature set is above the
room temperature.
➤
Select a lower temperature.
The temperature sensor is defective.
➤
Consult an authorised special-
ist workshop.
The vaporiser fan is damaged.
The condensor fan is damaged.
No heating
capacity
The ambient temperature is above
30 °C.
➤
Only use the heating function
of the roof air conditioner at
temperatures below 25 °C.
The device is not set to heating.
➤
Set the device to heating.
The temperature sensor is defective.
➤
Consult an authorised special-
ist workshop.
Low air output
The air intake section is clogged up.
➤
Ensure unhindered air supply
at the air intake units.
The vaporiser fan is damaged.
➤
Consult an authorised special-
ist workshop.
Water enters the
vehicle
The condensation water drainage
openings are clogged up.
➤
Clean the drainage openings
for condensation water.
The seals are damaged.
➤
Consult an authorised special-
ist workshop.
Air conditioner will
not go on
There is no voltage.
➤
Check the power supply.
The voltage is too low
(under 200 V).
The voltage converter is defective.
➤
Consult an authorised special-
ist workshop.
The temperature sensor is damaged.
The electrical fuse of the power sup-
ply is too low.
➤
Check the electrical fuse of the
power supply.
Air conditioner is
unable to be
switched off
The temperature sensor is defective.
➤
Consult an authorised special-
ist workshop.