Troubleshooting
CAM 1000 / BSC 01
EN
12
The CAM1000 / BSC 01 is automatically activated when the ignition is switched on.
As soon as an obstacle is in the active area, the dynamic arrow indicator (fig.
3
) appears in the
display. If the audible signal is connected, an evenly repeating beep will sound.
8.3
Operation at day and night
The monitor M75LXAHD from the BSV71000 system offers adjustment possibilities to adapt the
image to day and night operation. These settings must be made before connecting the blue line.
➤
For more information, please refer to the manual of the monitor M75LXAHD.
9
Troubleshooting
Fault
Cause
Solution
The device shows no
function.
The black or red cable for the
voltage supply are not making
contact.
Check that the connections are
secure.
The system plug is not con-
nected or not correctly plugged
into the control electronics.
Check the system plug and make
sure that it locks into place.
“NO SIGNAL” is dis-
played on the monitor.
No video signal present. Loose
contact in the plug connector of
the camera cable
Check that the connections are
secure.
The camera is defective.
Contact an authorized service
center to replace the camera.
CAM1000 was not connected to
camera input C3.
Make sure that CAM1000 is con-
nected to camera input C3.
A yellow GPS icon
appears on the monitor.
GPS reception is faulty.
The system is active but the
acoustic warning signal is off until
a better GPS reception is
obtained.
A red GPS icon appears
on the monitor.
No object detection is available.
Check that the connections are
secure.
The monitor will not
turn off.
The monitor was turned on man-
ually before connecting the blue
lines. In connection with
CAM1000 the keys are blocked.
The blue line must be discon-
nected and the monitor switched
off manually. Afterwards connect
the blue lines again.