INSTALLATION INSTRUCTIONS

4.  Remove upper duct from ceiling template and 

locate it over blower discharge.

Edges 

WITHOUT

  flanges  install  toward 

REAR

 and 

SIDE

 of opening. See (FIG. 6).

FIG. 6

Screw

Front

Lower

Upper

Sides Without Tab

To Rear And Side

Of Unit

5.  Use two (2) #10 x 10 mm screws to hold duct to 

base pan. Screw holes are provided in bottom of 

base pan for these screws.

6.  Reach up into return air opening of the unit and 

pull the unit electrical cord down for later con-

nection. See (FIG. 7).

7.  If your installation includes the optional electric 

heat kit, install it at this time. Follow the instruc-

tions with the heat package for its installation 

procedure.

FIG. 7

Pull Down 

Electric Cord

Measure Ceil-

ing Thickness

8.   Measure the ceiling to roof thickness:

a.  If distance is 25 mm - 51 mm, remove perfo-

rated tabs from both upper and lower ducts. 

See (FIG. 7) & (FIG. 8).

FIG. 8

Step a & b

Remove At 

Perforation

Step c

Use As 

Packaged

Upper Discharge 

Air Duct

Lower Discharge 

Air Duct

Step a

Remove At 

Perforation

b.  If distance is 51 mm - 76 mm, remove per-

forated tabs from bottom duct only. See  

(FIG. 8).

c.  If distance is 76 mm - 102 mm, install ducts 

as received. See (FIG. 8).

9.  Install ceiling template by sliding lower duct over 

upper duct.

10.  Hold the ceiling template up to the roof opening. 

a.  Start each mounting bolt through the ceiling 

template and up into the base pan by hand. 

See (FIG. 9).

FIG. 9

Mounting 

Bolts

Junction 

Box

Discharge 

Air Duct

Mounting 

Bolts

b.  Tighten all four (4) bolts until they touch the 

template but are not tight.

c. 

With the ceiling template flat against the ceil

-

ing install the 6 wood screws (installed sup-

plied) at an angle, so as to stretch and flatten 

the template. Three (3) across the front and 

three (3) across the back of the template. 

See (FIG. 10).

Содержание B3300 Series

Страница 1: ...12 2012 Dometic LLC LaGrange IN 46761 RECORD THIS INFORMATION FOR FUTURE REFERENCE Model Number Serial Number ADB Model Number ADB Serial Number Date Purchased Roof Top Unit Description Model Type Use...

Страница 2: ...TENANCE 11 A Air Filter 11 B Air Distribution Box Housing 11 C Fan Motor 11 D Frost Formation On Cooling Coil 11 E Heat Gain 11 F Condensation 11 SERVICE UNIT DOES NOT OPERATE 12 WIRING DIAGRAMS 12 A...

Страница 3: ...ion and instructions to avoid possible injury or death Read and understand these instructions be fore installing using servicing performing maintenance on this product Incorrect installation operation...

Страница 4: ...1 Unit 3 5 kW 2 Unit 5 0 kW Rating Plate 3313169 000 Height 333 mm Width 759 mm Depth 886 mm Weight 46 7 kg Dometic Marine gives GENERAL guidelines for genera tor requirements To reduce start up power...

Страница 5: ...t the front of the opening See FIG 3 INSTALLATION INSTRUCTIONS A Choosing Proper Location For Unit This unit is specifically designed for installation on the roof of a boat Mount only with front of un...

Страница 6: ...d discard carton 2 LIFTING HAZARD Use proper lifting technique and control when lifting product Failure to obey this caution could result in injury Place the unit on the roof 3 Do NOT slide unit Other...

Страница 7: ...25 mm 51 mm remove perfo rated tabs from both upper and lower ducts See FIG 7 FIG 8 FIG 8 Step a b Remove At Perforation Step c Use As Packaged Upper Discharge Air Duct Lower Discharge Air Duct Step a...

Страница 8: ...ply wire through Romex connector and into the junction box 152 mm leads are suffi cient for connection to unit wires and ground screw See FIG 12 FIG 13 FIG 12 Corner Reinforcement Heater Connection Un...

Страница 9: ...all 3 Screws In To Metal Template 3 Snap hole plug into place at rear of air distribu tion box See FIG 16 FIG 16 Wood Screw Hole Plug Wood Screw 4 Install four 4 8 x 16 mm wood screws that hold air di...

Страница 10: ...boat without cooling or heating There are three positions HIGH FAN MED FAN or LOW FAN to select from depending upon personal choice A Controls 1 The Selector Switch has 10 positions including OFF This...

Страница 11: ...n resume nor mal operation If frost condition persist contact your local service center for assistance E Heat Gain The ability of the air conditioner to maintain the desired inside temperature depends...

Страница 12: ...ocal service center for further help This unit must be ser viced by qualified service personnel only If any wiring or supply cord is damaged and needs to be replaced it must be replaced by the manufac...

Страница 13: ...ht to improve its products through changes in design or material without being obligated to incorporate such changes in products of prior manufacture Dometic can make changes at any time in design mat...

Страница 14: ...is out of warranty However based on the date the equipment is first put in service the item may still be covered by the Dometic warranty as described in Section A For proof of date put in service Dom...

Страница 15: ...on the original date of pur chase or date of installation 2 Proof of purchase or installation may be required to verify warranty coverage 3 Any unit or replacement part installed due to a warranty fai...

Отзывы: