EN
Troubleshooting
CFX3
36
Alert messages
A, page 15.
Alert message
Description
Possible cause
Suggested remedy
!ALERT - Lid open
> 3min
Lid open more
than 3 minutes
•
Lid not fully
latched
•
Internal fault
•
Check lid latched fully
•
Call the customer
service.
!ALERT - Voltage
low
The device has
stopped working
on DC due to low
voltage
•
Insufficient supply
voltage
•
Battery voltage is
too low
•
Battery protec-
tion is set too high
•
Check voltage drop
from battery to power
outlet and increase wir-
ing gauge if necessary
•
Test the battery and
charge as needed
•
Select a lower battery
protection setting
The device has
stopped working
on DC due to
abnormally high
voltage >31.5 V
(unlikely event –
for electronics
protection only –
uses same alert
message as low
voltage above)
•
Wrong DC supply
voltage
specification
•
Faulty supply
voltage
•
Internal fault
•
Ensure DC supply volt-
age specification
matches CFX3 product
rating label
•
Check DC voltage
supply and repair or
replace if faulty
•
Call the customer
service.