background image

EN

Operation

TCX14, TCX21, TCX35

12

6.5

Switch on the cooling box

A

Place the cooling device on a stable base.

Connect the cooling device

using the AC connection cable supplied (fig.

1

2, page 2) to an AC mains 

power socket or ...

using the DC connection cable supplied (fig.

1

3, page 2) to the DC socket 

in the vehicle (fig.

4

, page 3).

Press the button “

P

” at the control panel to switch on the cooling device.

The cooling device starts to cool or heat the interior space.

6.6

Switch over between cooling and heating

If you want to switch over between 

cooling 

and

 heating

, press the 

button “HOT/COLD”.

I

The red or blue operating display lights up and the device starts to cool/heat.

When you want to finish the cooling or heating process, press the button “

P

”.

When you stop using the cooling device, disconnect it from the mains.

6.7

Select temperature

The set temperature status display (fig.

3

5, page 2) indicates the selected 

temperature. With an increasing number of illuminated LEDs, the cooling or heating 
intensity also increases.

NOTICE! 

Take care that there are only objects or goods in the cooling device 
which may be cooled or heated to the selected temperature.

Operating display

Operating mode

red (fig.

3

2, page 2)

heating

blue (fig.

3

3, page 2)

cooling

NOTE 

The control unit of the cooling device has a memory function. 
It memorises the selected temperature range for each mode (cooling 
and heating). Thus the temperature range which is previously selected in 
the mode is set again with each switching on or switching over.

TCX14-TCX35-OPM-EMEA16.book  Seite 12  Montag, 6. Mai 2019  1:17 13

Содержание 9600014289

Страница 1: ...TCX14 TCX21 TCX35 Thermoelectric cooler Operating manual 5 EN MOBILE COOLING TCX14 TCX35 OPM EMEA16 book Seite 1 Montag 6 Mai 2019 1 17 13 TCX SERIES...

Страница 2: ...TCX14 TCX21 TCX35 2 3 2 1 4 1 2 1 2 3 4 5 6 3 TCX14 TCX35 OPM EMEA16 book Seite 2 Montag 6 Mai 2019 1 17 13...

Страница 3: ...TCX14 TCX21 TCX35 3 4 12 24 Vg 5 2 1 A B C 1 1 2 2 1 6 TCX14 TCX35 OPM EMEA16 book Seite 3 Montag 6 Mai 2019 1 17 13...

Страница 4: ...CX21 TCX35 4 1 5 2 L 450 323 250 303 208 201 260 328 7 1 5 2 L 550 340 460 376 265 350 TCX14 TCX21 TCX35 1 5 2 L 450 319 250 420 303 198 208 352 TCX14 TCX35 OPM EMEA16 book Seite 4 Montag 6 Mai 2019 1...

Страница 5: ...ols 5 2 Safety notes 6 3 Scope of delivery 9 4 Use as intended 9 5 Technical description 9 6 Operation 10 7 Cleaning and servicing 13 8 Disposal 14 9 Troubleshooting 14 10 Technical data 15 1 Explanat...

Страница 6: ...ncludingchildren with reducedphysical sensoryormentalcapabilities orlack ofexperience and knowledge unless they have been given supervision or instruc tion concerning use of the device by a person res...

Страница 7: ...o a DC outlet Disconnect the cooling device and other power consuming devices from the battery before connecting a quick charging device If the cooling device is connected to a DC outlet Disconnect th...

Страница 8: ...vices inside the cooling device unless they are recommended by the manufacturer for the purpose Do not place the cooling device near naked flames or other heat sources heaters direct sunlight gas oven...

Страница 9: ...t will automatically switch over to the energy save mode In this mode only the energy which is required to reach the temperature inside the box is consumed The cooling device is a low wear thermo elec...

Страница 10: ...ersal Thisprotectsthecooleragainstshort circuitingwhenconnectingto a battery NOTE Before you put the new cooling device into operation you should clean it inside and outside with a damp cloth for hygi...

Страница 11: ...attery monitor mode Slide the switch fig 1 4 page 2 to OFF in order to deactivate the battery monitor mode I 6 4 Opening the cooler TCX35 only Unlock the cooling device fig 2 page 2 Open the cooling d...

Страница 12: ...to finish the cooling or heating process press the button P When you stop using the cooling device disconnect it from the mains 6 7 Select temperature The set temperature status display fig 3 5 page 2...

Страница 13: ...a damp cloth NOTE The following temperature indications are subject to tolerances and are dependent on the measuring position Status display fig 3 5 page 2 Interior temperature Cooling 7 illuminated L...

Страница 14: ...in your vehicle The ignition must be switched on in most vehicles to apply current to the DC power socket The ignition is switched on and the cooling device does not work The DC power socket is dirty...

Страница 15: ...the inner ventilator is defective The thermo electric element is defective The integrated power unit is defective TCX14 TCX21 TCX35 Input voltage 12 24 Vg 220 240 Vw Power input 46 W 12 Vg 50 W 24 Vg...

Страница 16: ...num 77 kWh annum Gross capacity 14 l 21 l 35 l Usable capacity 13 5 l 20 l 33 l Climate class T Ambient temperature 16 C to 43 C Noise emission 41 dB A Weight 5 8 kg 7 3 kg 10 6 kg Inspection Certific...

Страница 17: ......

Отзывы: