EN
Display messages
RTX1000/2000, SPX1200
22
8.2
Control panel fault messages
The “ERROR” symbol (fig.
5, page 5) lights up if there is a fault with the parking
cooler. The type of error is shown on the display by the following error codes:
Display
text
Description
Cause
Remedy
F01
The compressor does not
work.
Error in compressor sensor
electrical supply (open
circuit).
➤
Switch off the system.
➤
Switch it on again after
30 min.
➤
If the fault occurs again,
contact an authorized
workshop.
F02
Error in compressor sensor
electrical supply (short
circuit).
F03
Compressor overload
F04
The condensor fan 1 does
not work.
No response from the fan.
F05
The condensor fan 1 is
overloaded.
Faulty fan speed
F06
The condensor fan 2 does
not work.
No response from the fan.
F07
The condensor fan 2 is
overloaded.
Faulty fan speed
F08
The evaporator fan does
not work.
No response from the fan.
F09
The evaporator fan is
overloaded.
Faulty fan speed
F10
The condensation water
that has formed is not
being discharged.
The condensation water
that has formed is not being
discharged.
F11
The system cannot
determine the internal
temperature.
Error in temperature sensor
electrical supply (open
circuit).
F12
Error in temperature sensor
electrical supply (short
circuit).
DometicRTX1000-RTX2000-SPX1200_OPM_4445101929_EMEA17_202x-xx-xx.book Seite 22 Donnerstag, 21. Oktober 2021 10:06 22