Installation
Fig. 3
4.1.3 Gas connection
n
The correct connection of the fridge has to
be carried out by a skilled specialist.
n
Note the particularly valid national rules for
usage of LG-driven appliances.
- Technical Standards EN 732
n
A preset pressure regulator
(1)
, Fig. 3, has
to be installed within the supplying line to
the fridge. The fridge must not be operated
with any other pressure than the one indica-
ted on the rating label.
n
The fridge has to be connected to the gas
bottle with a security hose.
n
Choose a sufficient length to connect the
hose pipe without kinks. The hose must not
be longer than 1.5 m.
n
The gas connection to the appliance is
effected by means of a suitable coupling
tube fitting L8, complying with EN 1949 (e.
g. Ermeto).
n
The hose has to be replaced within the
intervals settled in the particular national
rules.
n
After having connected the gas bottle, a
leak test at all joints and a burner flame test
have to be carried out. Use a leak indicating
spray or a foaming agent carrying out the
leak test. After having opened the bottle
valve check the joints for bubbles.
1
Bottle valve
SG 14
SG 17
Detail
1
Never use a naked flame to check the
appliance for leaks.
DANGER !
The refrigerator should only be operated using
liquid gas (propane, butane).
Do not use town gas or natural gas!
289 0317-90_2_EN_RGE4000_N1_Layout 1 03.02.2014 13:36 Seite 14
Содержание 9105705208
Страница 24: ...Seite 30...
Страница 46: ...Seite 30...
Страница 68: ...Seite 30...
Страница 69: ...1 RGE 4000 GR MBA 12 2013 N 1 289 0317 96_3_GR_RGE4000_N1_Layout 1 03 02 2014 13 34 Seite 1...
Страница 70: ...2 289 0317 96_3_GR_RGE4000_N1_Layout 1 03 02 2014 13 34 Seite 2...
Страница 71: ...3 n n n n n n n n 230V Dometic 289 0317 96_3_GR_RGE4000_N1_Layout 1 03 02 2014 13 34 Seite 3...
Страница 89: ...21 5 12 4 5 3 4 230 Dometic n n n 289 0317 96_3_GR_RGE4000_N1_Layout 1 03 02 2014 13 34 Seite 21...
Страница 90: ...Seite 30...