11
Dometic 8700 Series MasterFlush Toilet
Installation
5.5
Toilet system with through-the-wall
connections
1 . To route wiring and plumbing connections through the wall, use
floor template to locate the vertical centerline of each hole .
2 . Place toilet in proper position and mark horizontal centerlines
(fig .
21
) .
3 . Drill holes sizes as indicated on template .
4 . Route wiring and plumbing through holes, then follow toilet
installation instructions beginning at
Section 5.3 or Section 5.4,
step 4
.
21
6
RV installation appendix
CONVERSION TABLE
Wire – AWG to mm
2
Feet to Meters
AWG
14
12
10
Ft
10
15
20
30
50
mm
2
2 .5
4 .0
6 .0
M
3 .1
4 .6
6 .1
9 .2
15 .2
Wire size per length of run*
0-15 ft.
16-30 ft.
31-50 ft.
12 volts DC
#14
#12
#10
* Distance from circuit breaker to electronic control module .
WIRE SIZING CHART
When installing a Dometic macerator toilet in a recreation vehicle, please use the following wiring
information .
Installation notes
• Each toilet must have its own circuit breaker or fuse .
• Wire sizes must be appropriate for the installation . All other installation factors must be in accordance
with ISO electrical standards .
• Always use stranded copper wire (preferably tinned) .
• Always use crimp-type wire connections . Do not use wire nuts (they corrode) .
Warning!
Hazard of Shock or Fire:
Always use recommended fuse, circuit breaker and wire size .
Failure to do so can cause the loss of property and life .
Wiring / Electronic Control Module Connections