background image

9

FIG. 9

Disengage Tab

CCC 2 Thermostat

b.  Insert the 4 conductor communication cable 

through the hole in base plate. Align thermo-

stat base plate with hole in wall. Make sure 

base plate is level and attach base plate to 

wall using the 4 supplied screws.

c.  Insert the 4 conductor communication cable 

connector (RJ-11-6C4P) into the connector 

on the back of the thermostat. See (FIG. 10).

FIG. 10

4 Conductor

Communication Cable

d.  Align the thermostat with the back plate and 

snap into position.

G.  Installing The LCD SZ System

Wire colors listed for the communication ca-

ble (3-conductor cable) match the wire colors 

in the unit wire harness and the wire  harness 

at the LCD SZ electronic control box. Avail-

able wire colors may vary.

1.  Separate the cover from the LCD SZ thermostat 

by pressing down on the tab located at the bot-

tom of the base.

2.  Insert the previously run communication cable 

(3-conductor cable) through the hole in the base 

assembly.

3.  Cut back the outer cable shield approximately 3 

inches and strip 1/4″ insulation from each wire.

4.  Mount the thermostat level on the wall using the 

screws provided.

5.  Connect the wires. See (FIG. 11).
6.  Inspect all connections to make sure they are 

tight and not touching any other terminals or 

wires.

7.  Push the wires back through the base into the 

wall. Place the cover on the thermostat and 

push until an audible click is heard.

FIG. 11

12-

COMMS

12+

Communication 

Cable

 

Red/white wire to the 12V+ terminal

 

Black wire to the 12V– terminal

 

Orange wire to the "COMMS" terminal

INSTALLATION PROCEDURE

Содержание 640312 Series

Страница 1: ... 3314448 014 6 18 French 3314985 015_B 2018 Dometic Corporation LaGrange IN 46761 RECORD THIS INFORMATION FOR FUTURE REFERENCE Model Number Serial Number Date Purchased Roof Top Unit Description Model Use With Return Air Grille Model CCC 2 Electronic Control Kit CCC 2 Thermostat Indoor Temperature Sensor Kit Air Conditioner 640312 640315 3105007 XXX OR 3105935 XXX 3312020 000 3312024 XXX OR 331408...

Страница 2: ...ir Cover 14 M System Reset Checkout 14 N Furnace Aqua Temperature Differential Setting 14 GENERAL INFORMATION 15 A Frost Formation On Cooling Coil 15 B Heat Gain 15 C Condensation 15 D Air Distribution 15 WIRING DIAGRAMS 16 A Simple RV Wiring Diagram 16 B Unit Wiring Diagram 17 C 3312020 000 CCC 2 Electronic Control Kit Wiring Diagram 17 INTRODUCTION This air conditioner hereinafter referred to as...

Страница 3: ... all safety information and instructions to avoid possible injury or death Read and understand these instructions be fore installing using servicing performing maintenance on this product Incorrect installation operation servicing maintaining of this product can lead to seri ous injury Follow all instructions The installation MUST comply with all ap plicable local or national codes including the l...

Страница 4: ...people have had in actual applications When sizing the generator the total power usage of your RV must be considered Keep in mind generators lose power at high altitudes and from lack of maintenance CIRCUIT PROTECTION Time Delay Fuse or Circuit Breaker Required B Roof Requirements A 14 1 4 x 14 1 4 1 8 square opening hereinafter referred to as roof opening is required for installing this unit This...

Страница 5: ... c Check inside the RV for return air grille ob structions i e door openings room divid ers curtains ceiling fixtures etc See FIG 2 FIG 2 Dimensions Are Nominal 17 17 3 4 1 3 4 1 1 4 1 1 2 1 1 2 17 17 Roof Opening B Roof Preparation 1 FIRE OR ELECTRICAL SHOCK HAZARD Verify there are no obstacles inside RV s roof and or walls wires pipes etc Shut OFF gas supply disconnect 120 Vac power from RV and ...

Страница 6: ...Sizing Design Requirements See C Ta ble Air Distribution Duct Sizing Design on page 4 Alternate configurations and methods may be used which still allow the unit to operate properly however these alternate configurations and methods MUST be approved by Dometic Cor poration in writing The following in structions are based upon the use of Return Air Grille Kits 3105007 XXX 3105935 XXX 3 4 Min Leave ...

Страница 7: ...nto the roof opening 3 Route an indoor temperature sensor optional from the roof opening to the indoor temperature sensor location The 2 pin connector end goes to the roof opening See indoor temperature sensor installation instructions for proper sensor location 4 Route a 4 conductor communication cable from the roof opening to the thermostat mounting lo cation using the shortest most direct route...

Страница 8: ... with the in door temperature sensor for details of instal lation F Thermostat Indoor Temperature Sensor Thermostat Communication Cable Installation 1 The previously run communication cable 4 con ductor telephone cable must be terminated with two 2 RJ 11 6C4P telephone connectors Re fer to the crimp tool manufacturer for crimping instructions See FIG 6 FIG 7 RJ 11 6C4P connectors MUST be in stalle...

Страница 9: ... SZ electronic control box Avail able wire colors may vary 1 Separate the cover from the LCD SZ thermostat by pressing down on the tab located at the bot tom of the base 2 Insert the previously run communication cable 3 conductor cable through the hole in the base assembly 3 Cut back the outer cable shield approximately 3 inches and strip 1 4 insulation from each wire 4 Mount the thermostat level ...

Страница 10: ...er lifting technique and control when lifting product Failure to obey this caution could result in injury Place the unit on the roof 3 Do NOT slide unit Otherwise damage to gasket on bottom of unit may occur and could cause a leak Lift and place the unit over the prepared open ing using the gasket on the unit as a guide See FIG 12 FIG 12 FRONT Lift Place Do Not Slide 4 Place the electronic control...

Страница 11: ...4 mounting bolts EVENLY within 40 to 50 inch pounds See FIG 16 This will compress the roof gasket to approximately 1 2 6 Installation Of Divider Plate a Measure the ceiling to roof thickness If distance is 2 0 3 3 4 remove perfo rated tab from divider plate See FIG 17 If distance is 3 3 4 5 1 2 remove no tabs b Remove the backing paper from double sided tape located on ceiling template See FIG 17 ...

Страница 12: ...ling template e Locate the 1 8 x 7 x 18 self adhesive in sulation supplied with the return air grille kit Remove the backing paper from the insula tion and carefully stick onto the ceiling tem plate divider panel See FIG 19 FIG 19 Foam Tape Place Insulation In Position Do Not Cover Unit Rating Plate Divider Plate Excess width is intended to seal the di vider plate to the sides of the roof open ing...

Страница 13: ...o white black to black and green to green or bare copper wire using ap propriate size connectors e Tape the connectors to the supply wire to as sure they don t vibrate off f Push the wires into the electronic control box K System Configuration Now that the system is installed it is necessary to do a system configuration 1 Electronic Control Configuration Depending on the equipment options installe...

Страница 14: ...F mode c Simultaneously press the MODE and ZONE buttons The LCD will display IniT and all available zones d Release the MODE and ZONE buttons e Press the ON OFF button to exit system set up f When a dip switch is turned on after initial configuration a system reset will need to be done before the CCC 2 thermostat will rec ognize the updated selection 2 System Checkout Verify that all features of t...

Страница 15: ...side temperature is relatively low This may be prevented by ad justing the thermostat control knob to a warmer setting counter clockwise Should frosting con tinue operate on any FAN ONLY setting until the cooling coil is free of frost then resume nor mal operation If frost condition persist contact your local service center for assistance B Heat Gain The ability of this air conditioner to maintain...

Страница 16: ...16 WIRING DIAGRAMS A Simple RV Wiring Diagram OPTIONAL 12 VDC INPUT 2 WIRES 12 VDC INPUT 2 WIRES FIG 27 ...

Страница 17: ...17 WIRING DIAGRAMS B Unit Wiring Diagram C 3312020 000 CCC 2 Electronic Control Kit Wiring Diagram ...