AIR CONDITIONER  WIRING DIAGRAM

AIR BOX WIRING DIAGRAM

MOTOR

C

S

R

GRN/YEL

GRN/YEL

BLK

WHT

WHT

RED

WHT

115 VAC 60 HZ, 10

115 VAC 60 HZ, 10

USE COPPER CONDUCTORS ONLY

USE COPPER CONDUCTORS ONLY

FACTORY WIRING

FIELD WIRING

FIELD WIRING

LINE SPLICE

LINE SPLICE

GRN/YEL

COMPRESSOR

3105418.010

GRN/YEL

2

4

5
6

RED

WHT

WHT

RED

YEL

BLK

BLU

BLK

BRN

RED

YEL

BLK

1

3

WHT

WHT

TSTAT

ROTARY

SWITCH

BLK

BLK

WHT

HEAT ACCESSORY

115 VAC

115 VAC

START CAP

RUN

CAP

RED

COMP

R

C

S

START CAP

PTCR

HERM

C

FAN

RUN CAP

RUN CAP

THERMOSTAT

SWITCH

MOTOR

C

L1

1
2
4
H

HEAT ACCESSORY

SWITCH CONNECTION

SWITCH CONNECTION

OFF

HI FAN

HI FAN

MED FAN

MED FAN

LOW FAN

LOW FAN

L1-1

L1-2

L1-4

L1-4-H

L1-4-C

L1-2-C

L1-1-C

HEAT

LOW COOL

LOW COOL

MED COOL

MED COOL

HI COOL

HI COOL

O.L.

PTCR

ELEMENT

LIMIT SWITCH

1

2

4

L1

C

H

FAN

C

HERM

BLU

BLU

1

3

600312 & 600315 Series Installation Instructions

GRN/YEL

RUN CAP

RUN CAP

*

CAP

START

PTCR

3308032.008

*

SOME MODELS

SOME MODELS

NOT USED ON

NOT USED ON

COMPRESSOR

C

MOTOR

HERM

C

FAN

GRN/YEL

COMP STARTER

O.L.

R

*

S

PASSED

DIELECTRIC

4

6

5

3

2

6 PIN CONN

6 PIN CONN

1

RED

WHT

RED

YEL

BLK

WHT

RED

WHT

BRN

WHT

BLU

Содержание 600312.331

Страница 1: ...nance is performed This unit must be in stalled by a qualified service tech nician Modification of this product can be extremely hazardous and could result in personal injury or property damage Lire et comprendre ce manuel avant de procéderàl installation àdesréglages de l entretien ou des réparations L installation de cet appareil doit être effectuée par un réparateur qualifié Toute modification ...

Страница 2: ...ofs more than 4 00 inches thick C The ability of the air conditioner to maintain the desired inside temperature depends on the heat gain of the RV Somepreventativemeasurestakenbytheoccupantsofthe RVcanreducetheheatgainandimprovetheperformanceof theairconditioner Duringextremelyhighoutdoortempera tures the heat gain of the vehicle may be reduced by 1 Parking the RV in a shaded area 2 Using window s...

Страница 3: ...Dometic Corporation gives GENERAL guidelines for generator requirements These guidelines come from experiences people have had in actual applications When sizing the generator the total power usage of your recreational vehicle must be considered Keep in mind generators lose power at high altitudes and from lack of maintenance CIRCUIT PROTECTION Time Delay Fuse or HACR Circuit Breakers Required 600...

Страница 4: ... to failure in following these instructions 3 InstallationmustcomplywiththeNationalElectrical Code ANSI NFPA 70 and CSA Standard C22 1 latest edition and any State or Local Codes or regulations 4 DO NOT add any devices or accessories to this air conditioner except those specifically authorized by Dometic 5 This equipment must be serviced by qualified per sonnel and some states require these people...

Страница 5: ...eather sealant See FIG 5 FIG 5 FIG 6 Do Not Cut RoofStructure OrRafters Good Rafters Supported By CrossBeams Good Location Between Roof Rafters Frame Opening So It Won t Collapse When Bolting Down Unit Leave Access For Power Supply Wiring 15 Min At Front of opening 3 4 Min d If the opening exceeds 14 3 8 x 14 3 8 it will be necessary to re size the opening to 14 1 4 x 14 1 4 1 8 e If the opening i...

Страница 6: ...ionerandwillbeusedinsidethe RV See FIG 7 Thiscompletestheoutsidework Minoradjustmentscan be done from the inside of the RV if required F Installing The Air Conditioner 1 Removeairboxandmountinghardwarefromcarton The upper duct is shipped inside the lower duct which is part of the ceiling template 2 Check for correct alignment and adjust the unit as necessary RoofGasketcentersover14 1 4 1 8 opening...

Страница 7: ... over tightening is notnecessary G Wiring The System Disconnect 120 volt AC Failure to follow these instructions could create a shock hazard caus ing death or severe personal injury WARNING Reach up into the return air opening and pull the re maining wires down 1 Connection of 120 VAC refer to FIG 12 a Route power supply line through Romex con nector into junction box Tighten connector being caref...

Страница 8: ...quired to maintain the selected temperature level C Fan Operation 1 This will circulate the air in your RV without cooling or heating There are three positions HIGH FAN MED FAN or LOW FAN to select from depending upon personal choice See FIG 14 D HeatingOperation WithOptionalHeatKit Installed Note This electric heater will not replace a furnace for heating your RV in cold weather The intent is to ...

Страница 9: ...ng and producing power b If RV connected to power supply by a land line check to be sure line is sized properly to run air conditioner load and it is plugged into power supply c Check your fuse or circuit breaker to see if it is open d After the above checks call your local service center for further help This unit must serviced by qualified service personnel only 6 Whencallingforservice alwaysgiv...

Страница 10: ...P R C S START CAP PTCR HERM C FAN RUN CAP RUN CAP THERMOSTAT SWITCH MOTOR C L1 1 2 4 H HEAT ACCESSORY SWITCH CONNECTION SWITCH CONNECTION OFF HI FAN HI FAN MED FAN MED FAN LOW FAN LOW FAN L1 1 L1 2 L1 4 L1 4 H L1 4 C L1 2 C L1 1 C HEAT LOW COOL LOW COOL MED COOL MED COOL HI COOL HI COOL O L PTCR ELEMENT LIMIT SWITCH 1 2 4 L1 C H FAN C HERM BLU BLU 1 3 600312 600315 Series Installation Instructions...

Отзывы: