Dometic 3312024 series Скачать руководство пользователя страница 8

8

Special Features

Auto  Fan

When auto fan is selected the fan speed will vary depending on the difference be

-

tween the temperature set-point and the room temperature. In auto fan the compres

-

sor and fan cycle On and OFF with the thermostat.

When the difference is:

8º or more 

The fan operates on HIGH

5º to 7º  

The fan operates on MED

4º or less 

The fan operates on LOW

Zone Control

Zones are established at the time of the installation of your Dometic CCC 2 thermo

-

stat. A zone is an area of cooling/heating which is controlled independently by the 

CCC 2 thermostat. The CCC 2 thermostat allows for four zones (Air Conditioner/

Heat Pump) to be set up and run independent of each other. If you have one air con

-

ditioner/heat pump installed, you will have one zone. If your RV has more than one 

cooling/heating system, you may have 2, 3, or 4 zones. 

Your CCC 2 thermostat will operate cooling and heating appliances that your vehicle 

manufacturer has designed  to cool or heat specific areas (zones) of your RV. The 

CCC 2 thermostat will advise you of the number of zones in your RV. The zones are 

displayed 1, 2, 3, or 4 in the LCD readout. See 

“Quick reference to icons”

 on page 

3. In the event your vehicle has multiple zones designed, you have the freedom of 

selecting different modes of operations for each zone. To change from one zone 

to another, press the ZONE push-button on the CCC 2 thermostat. Each time the 

button is pressed and released the indicator will change the zone data displayed. 

When the zones have been programmed, the zones in operation will be displayed. 

To program each zone, simply repeat the programming steps shown in the operation 

section of this manual. 

Dehumidify (Select Models)

The Dometic CCC 2 thermostat will accommodate only one dehumidify air condi

-

tioner within the four zones. The dehumidify air conditioner can either be zone 1, 2, 

3, or 4. The dehumidify air conditioner must have the 

DEHUMIDIFY

 dip switch set to 

the ON position when the unit is installed.

When the relative humidity is above the humidity set-point the compressor will cycle 

ON and if the fan is in the AUTO mode it will run on LOW speed. If LOW, MED or 

HIGH speed is selected the fan will run in the speed selected. When the humidity is 

5% or less than the humidity set-point the compressor will cycle OFF.

The dehumidify feature does not permit operation under the following conditions:

 

•  Outdoor temperature is below 40º F. Resumes operation above 45º F.

 

•  Indoor temperature is below 62º F. Resumes operation above 65º F.

 

•  Indoor temperature is above 100º F. Resumes operation below 97º F.

 

•  When the zone with dehumidify is set to 

COOL

 mode and the indoor tem

-

perature is 2º F. above the 

COOL

 mode set-point. Resumes operation when 

indoor temperature is 2º F. below 

COOL

 mode set-point 

 

•  When the freeze sensor temperature is 27º F. or less. Resumes when freeze 

sensor temperature reaches 55º F.

 

•  If the system detects an error on any of the system temperature sensors.

When the system calls for furnace operation, the dehumidify feature will continue to 

operate unless one of the conditions above occurs. 

Program 1 & 2

The Dometic CCC 2 thermostat can store two operating programs. Each program 

can be set on individual zones with different mode and time settings for each zone. 

For each event the user can program the operating mode, fan speed, temperature 

set-point, and the time of day for the event.

1.  Select the zone to be programmed.

2.  Select program 1 by pressing the 

PROGRAM

 button. 

“PROG 1”

 icon will blink 

on the LCD display.

3.  Press the 

CLOCK

 button to set the time of day for program to start.

4.  Press the 

MODE

 button to select the mode of operation.

5.  Press the 

FAN

 button to select the fan speed.

6.  Press the 

PROGRAM

 button to save the 

“PROG”

 1 settings. LCD will now show 

“PROG 2”

.

To set program 2, repeat steps 3 - 5.

Press the Program button again to save programs in memory. Depending on the 

time of day, program 1 or 2 will begin immediately. For instance, if program 1 is set to 

begin at 10:00 AM and the time of day is 10:30 AM, program 1 will begin immediately. 

On the other hand, if program 1 is set to 10:00 AM and program 2 is set to begin at 

6:00 PM and the time of day is 7:00 PM, program 2 will begin immediately.   

Содержание 3312024 series

Страница 1: ...Comfort Control Center 2 Thermostat Operating Instructions Programmable Thermostat MODEL 3312026 XXX With Dehumidify 3312024 XXX With Out Dehumidify ...

Страница 2: ... the operation of the CCC 2 thermostat review the following diagrams and accompanying text that explain the functional characteristics of this system Your CCC 2 thermostat is equipped with a liquid crystal display LCD that identifies the mode of operation OFF Cool Heat Pump Fan Heat Strip Auto Furnace or Aqua temperature set point zone identification 1 2 3 4 fan speed Auto Low Med High program 1 a...

Страница 3: ... Mode Off Time 10 00 PM Your Dometic CCC 2 thermostat has been pre programmed Review settings below and adjust the settings to your personal comfort level Note Any time the CCC 2 is in an idle stage not illuminated you will need to wake it up by pressing any button on the CCC 2 before it will recognize a new setting at tempt Quick reference to LCD icons Temperature Humidity Set Point or Error Code...

Страница 4: ... sensor is located in the roof top unit The CCC 2 thermostat temperature measuring range is between 5 F and 105 F When the roof top unit is exposed to direct sunlight the upper limit of the CCC 2 thermostat could be reached even though the actual outdoor temperature is lower than 105 F Outside tempera tures above 105 F will be displayed as 105 F Clock Setting Press the CLOCK button to initiate the...

Страница 5: ...page 8 for more information on auto fan Mode Selection Press the MODE button and the LCD will display the first available mode Each suc cessive press will advance to the next available mode Continue to press the MODE button until the desired mode appears Depending on the systems installed your choices will be OFF COOL AUTO HP FURN or AQUA HS and FAN See Mode Description on page 6 7 for more inform...

Страница 6: ...t on the CCC 2 When the system calls for heating there will be a delay of approximately two minutes During this delay the hour glass icon will be displayed in the LCD In auto fan the compressor will turn ON first followed by the fan in approximately 15 seconds In this mode there are 4 fan speed selections LOW The fan operates continuously at low speed The compressor cycles On and OFF MED The fan o...

Страница 7: ...on on page 2 To set the 1 degree differential simultaneously press PROGRAM button and up button dIF1 will appear in the display while the buttons are pressed To set the 2 degree differential simultaneously press the PROGRAM button and the down button dIF2 will appear in the display while the buttons are pressed In this mode there are 4 fan speed selections LOW The fan operates continuously at low ...

Страница 8: ... humidity is above the humidity set point the compressor will cycle ON and if the fan is in the AUTO mode it will run on LOW speed If LOW MED or HIGH speed is selected the fan will run in the speed selected When the humidity is 5 or less than the humidity set point the compressor will cycle OFF The dehumidify feature does not permit operation under the following conditions Outdoor temperature is b...

Страница 9: ...Stage must be set to the ON position in order to configure the power module board for the on demand secondary stage operation in this example Zone 2 and Ext Stage DIP switches are in the ON position In this stage configuration the CCC 2 thermostat temperature set point will be used for both the primary and the secondary stage air conditioner heat pump Only one indoor temperature sensor is required...

Страница 10: ...cle will repeat itself until the outside temperature is greater than 42º F If the outside temperature becomes less than 30º F the heat pump will shut OFF and the auxiliary heat if provided will turn on Compressor Time Delay A time delay of approximately two minutes occurs any time the compressor is re quired to begin the cooling or heat pump cycle Power Interruption In the event the power to the a...

Страница 11: ...e settings are changed a system reset will need to be done before the CCC 2 thermostat will recognize the updated selection To do a system reset Make sure the CCC 2 thermostat is in the OFF mode Simultaneously press the MODE and ZONE buttons The LCD will display IniT and all available zones Release the MODE and ZONE buttons Press the ON OFF button to exit system set up System Reset Procedure ...

Страница 12: ...ain of the vehicle may be reduced by 1 Parking the RV in a shaded area 2 Using window shades blinds and or curtains 3 Keeping windows and doors shut or minimizing usage 4 Avoiding the use of heat producing appliances Operation on High Fan Cooling mode will give optimum or maximum efficiency in high humidity or high outside temperatures Starting the air conditioner early in the morning and giving i...

Отзывы: