Dometic 3253.332 Скачать руководство пользователя страница 3

3

Type 3253.332 Installation and Operating Instructions

A. Precautions

Improper installation; may damage equip-
ment; could endanger life; cause serious in-
jury and/or property damage.

1.

Read Installation and Operating Instructions care-
fully before attempting to start your air conditioner
installation.

2.

Dometic Corporation will not be liable for any dam-
ages or injury incurred due to failure in following
these instructions.

3.

The equipment shall be installed in accordance with
nation wiring regulation per ICE 335-2-40, 7.12.1.In-
stallation must comply with applicable codes or
regulations.

INSTALLATION INSTRUCTIONS

SPECIFICATIONS

The Manufacturer gives only general guidelines for Generator
requirements. These Generator requirements come from
experiences consumers have with our equipment in field
applications. When sizing Generators, the total electrical
power consumption of the caravan must be considered. Keep
in mind that Generators lose power because of altitude
increase above sea level, high outside temperatures and lack
of maintenance.

Type

3253.332

Electric

Air Cond

Heater

Nominal Capacity (KW)

3.2

1.6

Electrical  Rating

220 - 240 VAC 50 Hz. 1Ph.

FL Amps (Comp/Motor) 5.2/1.6

6.3/1.6

LR Amps (Comp/Motor) 26/4.4

--/4.4

Power (KW)

1.3

1.9

Min. Wire Size

Up to 8 meters, use 1.5mm

2

 Copper

Circuit Protection

10 Amp Time Delay Fuse or
10 Amp Circuit Breaker

Generator Size

1 Unit

3.5 KW

2 Units

5.0 KW

5.

This equipment must be serviced by qualified per-
sonnel and some localities require these people to
be licensed.

B. CHOOSING PROPER LOCATION FOR THE

AIR CONDITIONER

This air conditioner is specifically designed for installa-
tion on the roof of a recreational vehicle (Caravan). When
determining your cooling requirements, the following
should be considered:

Size of Caravan;

Window area (increases heat gain);

Amount of insulation in walls and roof;

Geographical location where the Caravan will be
used;

Personal comfort level required.

1.

Normal Location-The air conditioner is designed to
fit over an existing roof vent opening. When the vent
is removed, it normally creates a 35.5 cm x 35.5 cm

opening. See FIG. 1.

FIG. 1

2.

Other Locations-When no roof vent is available or
another location is desired, the following is recom-
mended:
a.

For one unit installation :
The air conditioner should be mounted slightly
forward of the center (front to back ) and cen-
tered from side to side on the Caravan. See FIG.
2.

1/2L

L

L

1/3L

2/3L

FIG. 2

L = Length

b.

For two unit installations:
Install one air conditioner 1/3 and the other 2/3's
back from the front of the caravan and centered
from side to side. See FIG. 2.

D. Condensation

Note: The manufacturer of this air conditioner will not be
responsible for damage caused by condensed moisture on
ceilings or other surfaces. Air contains moisture and this
moisture tends to condense on cold surfaces. When air
enters the Caravan, condensed moisture may appear on the
ceiling, windows, metal parts, etc. The air conditioner re-
moves this moisture from the air during normal operation.
Keeping doors and windows closed when this air conditioner
is in operation will minimize condensed moisture on cold
surfaces.

4.

DO NOT add any devices or accessories to this air
conditioner except those specifically authorized by
Dometic.

Содержание 3253.332

Страница 1: ...qualified service tech nician Modification of this product can be extremely hazardous and could result in personal injury or property damage MODEL B3200 Roof Top Air Conditioner used with Mechanical A...

Страница 2: ...t 50 HZ at all times B This Air Conditioner Is Designed For 1 Installationonarecreationalvehicleduringthetime the vehicle is manufactured 2 Mounting on the roof of a recreational vehicle 3 Roof constr...

Страница 3: ...o be licensed B CHOOSINGPROPERLOCATIONFORTHE AIR CONDITIONER This air conditioner is specifically designed for installa tionontheroofofarecreationalvehicle Caravan When determining your cooling requir...

Страница 4: ...Kg when the Caravan is in motion Normally a 90 Kg static load design will meet this require ment See FIG 7 54 cm KEEP THESE AREAS FREE OF OBSTRUCTIONS 30 cm REAR OF UNIT 10 cm 10 cm 10 5 cm 18 cm 18 c...

Страница 5: ...at the front of the opening See FIG 6 It is the responsibility of the installer of this air conditioner system to ensure structural integrity of the Caravan roof Never create a low spot on the roof w...

Страница 6: ...omceilingtemplateandlocate it over blower discharge See FIG 9 FIG 8 FRONT FIG 10 Step a Remove At Perforation Step b Remove At Perforation Step c UseAs Packaged Upper Discharge AirDuct Lower Discharge...

Страница 7: ...permanent connection or wire a molded plug into the junction box for a plug in connection a If a Permanent Connection Route the power supply line previously installed to the roof open ing into the ju...

Страница 8: ...ut coolingorheating Therearethreepositions HIGH FAN 3 MED FAN 2 or LOW FAN 1 to select from dependinguponpersonalchoice SeeFIG 14 D HeatingOperation WithOptionalHeatKit Installed Note This electric he...

Страница 9: ...otorgenerator check to be sure motor generator is running and producingpower b IfCaravanconnectedtopowersupplybyaland line check to be sure line is sized properly to run air conditioner load and it is...

Страница 10: ...HI 4 2 1 MOTOR FAN CAP 220 240 V 220 240 V 50Hz HEATER THERMOSTAT PTCR START CAP RUN CAP RUN CAP COMPRESSOR R C S FACTORY WIRING FIELD WIRING FIELD WIRING ELECTRICAL BOX COMP PTCR START CAP FAN CAP C...

Отзывы: