NDS Surgical Imaging, LLC
5750 Hellyer AvenueSan Jose CA 95138-1000 USAwww.ndssi.com
NDS Surgical Imaging BV
Nijverheidscentrum 282761 JP Zevenhuizen (ZH)
The Netherlands
+31 180 63 43 56 Tel+31 180 63 21 91 Fax
Страница 1: ...Dome Ex Display User s Guide ...
Страница 2: ...products from other vendors does not imply any recommendation or endorsement This document contains proprietary information protected by copyright No part of this manual may be reproduced by any mechanical electronic or other means in any form without prior written permission of NDSsi NDS Surgical Imaging NDSsi the NDSsi logo Dome the Dome by NDSsi logo Dome E2cHB Dome E3 Dome E3cHB Dome E5 are ei...
Страница 3: ...es with the DICOM Part 14 Standard The all digital design enables the display to produce the sharp crisp images critical to softcopy medical viewing Unwanted analog display image artifacts are eliminated For display classification and intended use environmental guidelines safety precautions handling cleaning and storage tips and specifications see Technical Information on page 6 System Requirement...
Страница 4: ... Ex Display Some Dome Ex displays ship with a DC adapter that operates per power switch For Dome E3cHB unit only Dome Ex display mounted on desk stand DC power adapter Power cords DVI cable DisplayPort cable ...
Страница 5: ... 8 pin port on Dome E2cHB Dome E3 and Dome E5 and 6 pin port on Dome E3cHB Video input Drives the data to the display All Dome Ex displays have a standard DVI connector The Dome E3cHB unit also includes a DisplayPort connector port Reset button Restores the display configuration to default setting LED lights Provides information on the status of the display NOTE Usage of the USB B port on Dome E3c...
Страница 6: ...ecure the connection 2 Plug the power cord into the power input port on the connector plate 3 Plug the other end of the video cable into the video port on your computer system Secure the connection 4 Plug the other end of the power cord into the power supply 5 Plug the power supply cord s into a grounded AC outlet 6 If you are using a BridgePower adapter turn on the adapter power switch before you...
Страница 7: ...rom portrait to landscape for better access to the ports Threading cables Thread the DVI cable and power cord through the stand column Make sure the cable and cord run through the notches To reattach the stand cover align the hooks with the slots on the stand Press the cover into place A click sound signals a secure connection ...
Страница 8: ...oxide Mode of Operation Continuous No applied part Important recycle instruction HAZARDOUS SUBSTANCE Lamp s inside this product contain mercury This product may contain other electronic waste that can be hazardous if not disposed of properly Recycle or dispose in accordance with local state or federal laws For more information contact the Telecommunications Industry Association at WWW ECYCLINGCENT...
Страница 9: ...mportant precautions about electric shock Read the accompanying text carefully to prevent damage to display components and to guard your safety DIRECT CURRENT BAROMETRIC PRESSURE Transport and storage 12 000 meters 39 400 feet maximum in unpressurized container RELATIVE HUMIDITY Transport and storage 5 to 90 noncondensing TEMPERATURE Transport and storage 10 to 60 C for Dome E3 Dome E3cHB and Dome...
Страница 10: ...playing and viewing of medical images including radiographs of the breast for review and analysis by trained medical practitioners WARNING In the Dome Ex display series only the Dome E5 display can be used for primary image diagnosis in mammography The Dome E2cHB Dome E3 and Dome E3cHB units must not be used for primary image diagnosis in mammography Federal law restricts this device to sale by or...
Страница 11: ...S WITH PROTECTIVE EARTH Safety tips Never open the display case even when the power is off Dangerous voltage inside may cause electric shock or death To avoid damage to the display use the grounded power supply and video cable supplied by NDSsi or use certified replacements Be sure the display is electrically grounded You must connect the third grounding pin on the US power cord to a grounded outl...
Страница 12: ...nto a standard VESA 100 mm mounting unit if you elect not to use the desk stand Do not set up the display near strong light or heat sources Do not block the vents on the back of the display or install the display in a built in enclosure Blocked vents cause excessive heat to build up inside the display increasing risk of fire When installing components turn off your computer but leave it plugged in...
Страница 13: ...to water or excessive moisture Do not allow water or other stains to stand on the unit Wipe liquids off immediately to prevent damage to the display case and the screen Shipping storing the display Keep the display in its shipping container until installation Return the display to its original container whenever you need to store the unit move it to another location or return it for repair The pac...
Страница 14: ...ith 0 3 JND precision Colors supported 16 7 M Pixel arrangement RGB vertical stripe Interface Display control brightness contrast DDC2B Display identification EDID read using DDC2B Display status Dual stack tricolor LEDs on back panel Panel Connectivity Video input DVI D Pixel data sizes 8 bit 16 bit and 24 bit per pixel color VGA compatibility 640 x 480 to 1280 x 1024 USB interface Built in USB 2...
Страница 15: ...tion Wattage 60 W typical Physical Size 228 6 mm x 76 2 mm x 50 8 mm 9 in x 3 in x 2 in Weight 1 3 kg 2 75 lb Characteristic item Specification Display MTBF 50 000 hours Backlight MTBF 50 000 hours to 50 brightness with backlight on continuously Characteristic item Specification EMI shielding No emission of low level radiation Temperature Operating range 10 C 40 C Storage range 20 C 60 C Humidity ...
Страница 16: ...ay programmable gamma from palette of up to 3061 shades Pixel arrangement Subpixel vertical stripe Interface Display control brightness contrast DDC2B Display identification EDID read using DDC2B Display status Dual stack tricolor LEDs on back panel Panel Connectivity Video input Dual Link DVI D Pixel data sizes 8 bit and 10 bit per pixel grayscale 24 bit color mapped to luminance VGA compatibilit...
Страница 17: ...on Wattage 60 W typical Physical Size 228 6 mm x 76 2 mm x 50 8 mm 9 in x 3 in x 2 in Weight 1 3 kg 2 75 lb Characteristic item Specification Display MTBF 50 000 hours Backlight MTBF 50 000 hours to 50 brightness with backlight on continuously Characteristic item Specification EMI shielding No emission of low level radiation Temperature Operating range 10 C 40 C Storage range 10 C 60 C Humidity Op...
Страница 18: ...grammable gamma from palette of up to 2041 shades Pixel arrangement R G B vertical stripe Interface Display control brightness contrast DDC2B Display identification EDID read using DDC2B Display status Dual stack tricolor LEDs on back panel Panel Connectivity Video input DisplayPort 1 1 and Dual Link DVI D Pixel data sizes 8 bit 16 bit 24 bit and 30 bit per pixel color 30 bit color is supported on...
Страница 19: ...Wattage 81 W typical Physical Size 223 5 mm x 90 0 mm x 56 6 mm 8 8 in x 3 5 in x 2 2 in Weight 1 4 kg 3 lb Characteristic item Specification Display MTBF 50 000 hours Backlight MTBF 50 000 hours to 50 brightness with backlight on continuously Characteristic item Specification EMI shielding No emission of low level radiation Temperature Operating range 10 C 40 C Storage range 10 C 60 C Humidity Op...
Страница 20: ...gray programmable gamma from palette of up to 3061 shades Pixel arrangement LCR vertical stripe Interface Display control brightness contrast DDC2B Display identification EDID read using DDC2B Display status Dual stack tricolor LEDs on back panel Panel Connectivity Video input Dual Link DVI D Pixel data sizes 8 bit and 10 bit per pixel grayscale 24 bit color mapped to luminance VGA compatibility 6...
Страница 21: ...on Wattage 55 W typical Physical Size 228 6 mm x 76 2 mm x 50 8 mm 9 in x 3 in x 2 in Weight 1 3 kg 2 75 lb Characteristic item Specification Display MTBF 50 000 hours Backlight MTBF 50 000 hours to 50 brightness with backlight on continuously Characteristic item Specification EMI shielding No emission of low level radiation Temperature Operating range 10 C 40 C Storage range 10 C 60 C Humidity Op...
Страница 22: ...x 1600 1600 x 1200 Portrait Landscape 32 bit Dome E3 1536 x 2048 2048 x 1536 Portrait Landscape 32 bit 32 bit palette is used for 256 and 1024 shades of gray Dome E3cHB 1536 x 2048 2048 x 1536 Portrait Landscape 32 bit 32 bit palette is used for 16 7 million and 1 06 billion colors Dome E5 2048 x 2560 2560 x 2048 Portrait Landscape 32 bit ...
Страница 23: ...splay Video Port DIN Connector Power Input Adapter Dome E2cHB Dome E3 or Dome E5 DVI 8 pin 12V 5 130 W BPC BPM130S12F02 with power switch Dome E3cHB DVI and DisplayPort 6 pin 24V 5 150 W BPC BPM150S24F05 with power switch 6 pin connector on Dome E3cHB display 8 pin connector on Dome E2cHB Dome E3 and Dome E5 1 GND VCC 6 VCC 4 3 GND 2 GND VCC 5 VCC 7 VCC 8 1 GND VCC 5 3 GND 2 GND VCC 6 4 GND ...
Страница 24: ...x displays provide information about the display LED A describes the digital link status between the display controller and the interface LED B describes the display panel status it shows any faults currently in the panel Reset button left and LEDs on interface plate LED A top LED B ...
Страница 25: ...nce LED B Action Sequence Dark Initial power on Flashing yellow Initial power on Blink yellow Self test Solid yellow Power on self test Dark One 1 second after power on Flashing green Self test pass LED Status Description Solid green Functional link normal operation Flashing yellow Link working unrecognized sync information LED Status Description Solid green Functional system normal operation Flas...
Страница 26: ...a more recent version The installation CD contains a file older than the one currently on your system The Confirm File Replace dialog box appears if the installation CD contains a file older than the one currently on the system Click No to the question Over write the newer file Or click No to All Unable to set the maximum or native resolution of the display The function Hide all modes that this mo...
Страница 27: ...laws WARNING Users of Dome E3cHB and Dome E5 Displays The Dome E3cHB and Dome E5 displays are Class A products In a domestic environment either of these products may cause radio interference in which case the user may be required to take adequate measures Radio transmitting equipment cellular phones etc shall not be used in close proximity of the devices since this could influence the performance ...
Страница 28: ...display was classified as required by the MDD according to Annex IX of the directive and the medical device MEDDEV guidance available at the time of classification Because the display uses electrical energy and has no direct patient connections and by itself no medical utility the display is classified according to Rule 12 as an MDD Class I device component or accessory The MDD states that manufac...
Страница 29: ... 2006 and IEC EN 60601 1 2 and third party test reports and certifications a risk hazard analysis an essential requirements checklist and the NDS Surgical Imaging European Community CE marking directive Declaration of Conformity NDS Surgical Imaging located in San Jose Calif USA is the manufacturer of these displays in the meaning of the directive As required by the MDD in Article 14 NDS Surgical ...
Страница 30: ...l standard electromagnetic compatibility requirements EN 55011 Limits and methods of measurements for radio interference characteristics of industrial scientific and medical equipment IEC 1000 3 2 Harmonic emissions IEC 1000 3 3 Voltage fluctuations flicker emissions IEC 1000 4 2 Electrostatic discharge requirements for industrial process measurement and control equipment IEC 1000 4 3 Radiated ele...
Страница 31: ...energy and if not installed and used in accordance with the instruction may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to corre...
Страница 32: ... operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his o...
Страница 33: ... Group 1 The Dome E series uses RF energy only for its internal function Therefore its RF emissions are very low and are not likely to cause any interference in nearby electronic equipment RF emissions CISPR 11 Class B The Dome E series is suitable for use in all establishments including domestic establishments and those directly connected to the public low voltage power supply network that suppli...
Страница 34: ...al commercial or hospital environment Surge IEC 61000 4 5 1 kV line s and neutral 1 kV line s and neutral Mains power quality should be that of a typical commercial or hospital environment Voltage dips short interruptions and voltage variations on power supply input lines IEC 61000 4 11 5 UT 95 dip in UT for 0 5 cycle 40 UT 60 dip in UT for 5 cycles 70 UT 30 dip in UT for 25 cycles 5 UT 95 dip in ...
Страница 35: ...iance level in each frequency range b interference may occur in the vicinity of equipment marked with the following symbol Radiated RF IEC 61000 4 3 3 V m 80 MHz to 2 5 GHz 3 V m NOTE 1 At 80 MHz and 800 MHz the higher frequency range applies NOTE 2 hese guidelines may not apply in all situations Electromagnetic propagation is affected by absorption and reflection from structures objects and peopl...
Страница 36: ...AXIMUM OUTPUT POWER OF TRANSMITTER W SEPARATION DISTANCE ACCORDING TO FREQUENCY OF TRANSMITTER m 150 kHz to 80 MHz 80 MHz to 800 MHz 800 MHz to 2 5 GHz 0 01 0 12 0 12 0 23 0 1 0 38 0 38 0 73 1 1 2 1 2 2 3 10 3 8 3 8 7 3 100 12 12 23 For transmitters rated at a maximum output power not listed above the recommended separation distance d in meters m can be estimated using the equation applicable to t...
Страница 37: ...lsory Certification regulating safety and EMC GB4943 2011 GB9254 2008 GB17625 1 2012 Class A Dome E3cHB and Dome E5 TÜV Rheinland GM Mark for medical products Voluntary Control Council for Interference by information technology equipment sold in Japan Class A Dome E3cHB and Dome E5 Class B Dome E2cHB and Dome E3 Korea Certification ...
Страница 38: ... the Dome Ex Dome Sx color display excluding the Dome E4c is determined by NDSsi to be less than 250 cd m NDSsi will repair or replace the display at its sole discretion The display must have been run in native color mode at or below the CXtra default brightness setting as configured from the factory If within 5 years of initial purchase the maximum output of the Dome E4c color display is determin...
Страница 39: ...products purchased through a distributor reseller or medical device manufacturer other than NDSsi each an Intermediary where such Intermediary provides direct warranty service to its end user customers in connection with such product DISCLAIMER This limited product warranty sets forth your sole and exclusive remedy and NDSsi s sole and exclusive liability under the Standard Limited Warranty descri...
Страница 40: ...ay vary from locality to locality Some localities do not allow limitations on implied warranties and or do not allow the exclusion of incidental or consequential damages so the above limitations might not apply to you WARRANTY SERVICE REPAIR RETURN U S LATIN AMERICA AND CANADA ONLY Our standard warranty service is Repair and Return Repair and Return requires the defective unit to be returned to ou...
Страница 41: ...ervice technician will evaluate the unit and confirm the failure description provided by the customer a If the found failure type is covered under warranty the repair parts labor and shipment back to the customer will be at no charge b If the found failure type is not covered under warranty NDSsi s then current evaluation fee will apply in addition to the cost of parts labor and the return shipmen...
Страница 42: ...s sole discretion to request pre payment for any nonwarranty repairs NPF evaluations and return shipping charges prior to return of the product to customer Any invoiced amount not paid when due shall be subject to a service charge equal to the lesser of one and one half percent 1 5 per month or the maximum rate permitted by law If NDSsi undertakes collection or enforcement efforts customer shall b...
Страница 43: ...ht display Dome E5 display 933 0544 5 megapixel grayscale display Power adapter 6 pin 902 0174 Power block 24V 150W with 6 pin DIN connector for use with the Dome E3cHB display Power adapter 8 pin 902 0173 Power block 12V 130W with 8 pin DIN connector for use with the Dome E2cHB Dome E3 or Dome E5 display Power cord US 903 0500 Medical grade power cord for use in the United States Power cord EU 90...
Страница 44: ...Surgical Imaging LLC 5750 Hellyer Avenue San Jose CA 95138 1000 USA www ndssi com NDS Surgical Imaging BV Nijverheidscentrum 28 2761 JP Zevenhuizen ZH The Netherlands 31 180 63 43 56 Tel 31 180 63 21 91 Fax ...