Communication 
 

The units communicate with a controller (master) over RS485 using Modbus RTU and 
thus  they  can  be  used  in  a  number  of  control  and  SCADA  systems.  The  register 
description  is  available  in  a  separate  document 

Room  units  UI... 

  Communication 

description.

  User  manual  for  domat.exe  and  detailed  description  of  the  room  unit 

functions find in the document 

Room units configuration 

 User manual. 

 

Display 

 

A large (60 x 60 mm) display clearly shows 
actual  room  temperature  and  controller 
status  with  7-segment  digits  and  standard 
Day,  Night,  Off,  and  Time  scheduler 
symbols.  Active  output  is  indicated  by  a 
heating symbol. In the upper part, there are 
week  days  used  for  time  scheduler  setup. 
Other symbols are not used. 
 
 
LCD symbol set 
 

Dimensions 

UI300, UI300BL 

 

 
 
 
 
 
 
 
 
 
 
 
 

Содержание UI300

Страница 1: ...plication Air handling units and air condition in rooms with variable load schools cinemas lecture halls etc Systems with water or electrical floor heating control and measuring of room temperature Monitoring and recording of temperature indoors Function The units acquire temperature and relative humidity in the room temperature correction controlled by the knob and required operation status which...

Страница 2: ...g actual temperature and humidity The unit Modbus address and functionality is defined over the RS485 interface with service software ModComTool which is free for download at http domat int com en downloads software To interface the room unit to the computer use the USB 485 converter M080 RS232 RS485 converter R012 or any suitable RS485 converter ___________________________________________________...

Страница 3: ...perature sensor Pt1000 2 AGND exteral temperature sensor Pt1000 3 DI1 input presence window 4 DO1 output for heating valve 5 G0 power outputs common point 6 G0 power outputs common point 7 G power 8 K communication RS485 9 K communication RS485 DIP switches Back of the PCB BUS END if ON the bus is terminated if last device on the line USR not used reserved for future applications INIT sets the con...

Страница 4: ...by 2 or 4 screws to any flat surface or a flush mounting box Ø 50 mm At the back of the bottom there is an aperture for cabling The bottom should be installed and cabling connected first and the upper part inserted after the construction works have been finished to prevent damage to the unit Seal the conduits to avoid influencing the sensor by draught Use insulating pad when installing the sensor ...

Страница 5: ...escription User manual for domat exe and detailed description of the room unit functions find in the document Room units configuration User manual Display A large 60 x 60 mm display clearly shows actual room temperature and controller status with 7 segment digits and standard Day Night Off and Time scheduler symbols Active output is indicated by a heating symbol In the upper part there are week da...

Страница 6: ...ditioning systems It must not be used for protection of persons against health risks or death as a safety element or in applications where its failure could lead to physical or property damage or environmental damage All risks related to device operation must be considered together with design installation and operation of the entire control system which the device is part of ...

Страница 7: ...domat UI300 12 2019 Subject to technical changes 7 Changes in versions 09 2019 First datasheet version 12 2019 I O position corrected ...