MXH94x / MXH95x Transparent Adapter User’s Guide –

 Dolphin Interconnect Solutions  

 

 

 Page 8 

MXH94x MTBF by Temperature and Environment 

The MTBF (in hours) for the MXH94x with 1, 2 or 4 Gen4 FireFly modules mounted can be found in the table below. The numbers are 
calculated using the Telcordia SR-332 issue 2 (2006) standard. 

 

Ambient 

Temp. 

[°C] 

MXH94x 

 1 FireFly 

mounted 

MXH94x 

 2 FireFly 

mounted 

MXH94x 

4 FireFly 
mounted 

        3.695.205  

   3.043.158  

   2.249.339  

        3.085.401  

   2.497.241  

   1.807.952  

10 

        2.555.388  

   2.037.075  

   1.449.193  

15 

        2.100.911  

   1.653.639  

   1.159.806  

20 

        1.716.081  

   1.337.251  

      927.674  

25 

        1.393.934  

   1.078.290  

      742.173  

30 

        1.126.968  

      867.705  

      594.276  

35 

           907.657  

      697.322  

      476.485  

40 

           728.823  

      559.986  

      382.683  

45 

           583.891  

      449.592  

      307.936  

50 

           467.021  

      361.019  

      248.302  

55 

           373.156  

      290.036  

      200.648  

Table 1: MXH94x MTBF vs. Temperature for Ground Fixed, Controlled (GB) Environment 

MXH95x MTBF by Temperature and Environment 

 

The MTBF (in hours) for the MXH95x with 1, 2 or 4 Gen3 FireFly modules mounted can be found in the table below. The numbers are 
calculated using the Telcordia SR-332 issue 2 (2006) standard. 

 

Ambient 

Temp. 

[°C] 

MXH95x 

 1 FireFly 

mounted 

MXH95x 

2 FireFly 

mounted 

MXH95x 

4 FireFly mounted 

        3.695.205  

   3.043.158  

   2.249.339  

        3.085.401  

   2.497.241  

   1.807.952  

10 

        2.555.388  

   2.037.075  

   1.449.193  

15 

        2.100.911  

   1.653.639  

   1.159.806  

20 

        1.716.081  

   1.337.251  

      927.674  

25 

        1.393.934  

   1.078.290  

      742.173  

30 

        1.126.968  

      867.705  

      594.276  

35 

           907.657  

      697.322  

      476.485  

40 

           728.823  

      559.986  

      382.683  

45 

           583.891  

      449.592  

      307.936  

50 

           467.021  

      361.019  

      248.302  

55 

           373.156  

      290.036  

      200.648  

                         Table 2: MXH95x MTBF vs. Temperature for Ground Fixed, Controlled (GB) Environment 

Содержание MXH94x

Страница 1: ...MXH94x MXH95x Transparent Adapter User s Guide Dolphin Interconnect Solutions Page 1 Dolphin MXH94x MXH95x Transparent Adapter Users Guide Version 1 1 Date 22th March 2022...

Страница 2: ...MXH94x MXH95x Transparent Adapter User s Guide Dolphin Interconnect Solutions Page 2...

Страница 3: ...FIGURE THE BOARD FOR PROPER OPERATION 11 STEP 4 INSTALL THE ADAPTER CARD 11 STEP 5 INSTALLING AND REMOVING CABLES 11 Connecting Cables 11 Disconnecting Cables 11 STEP 6 INSTALLING THE DOLPHIN MANAGEME...

Страница 4: ...EXTENT PERMITTED BY LAW DOLPHIN WILL NOT BE LIABLE FOR ANY INDIRECT INCIDENTAL SPECIAL OR CONSEQUENTIAL DAMAGES INCLUDING LOST PROFITS LOST DATA OR LOSS OF USE ARISING OUT OF ANY USE OF DOLPHIN S PRO...

Страница 5: ...operation Transparent Hot Add Attaching an IO Expansion system after the server is booted Target mode The card is installed in an expansion chassis or backplane for Transparent IO expansion Lane One P...

Страница 6: ...x16 2 x8 2 units 24 fiber MPO MXH945 4 x4 Transparent x16 2 x8 4 x4 4 units 12 fiber MPO MXH946 1 x8 Transparent x8 1 unit 24 fiber MPO MXH947 2 x4 Transparent x8 2 x4 2 units 12 fiber MPO MXH948 1 x4...

Страница 7: ...ches Host clock isolation Automatic support for host running CFC or SSC mode VAUX powered board management controllers for flexible configuration and cable management Flash recovery option PFX Multi c...

Страница 8: ...92 307 936 50 467 021 361 019 248 302 55 373 156 290 036 200 648 Table 1 MXH94x MTBF vs Temperature for Ground Fixed Controlled GB Environment MXH95x MTBF by Temperature and Environment The MTBF in ho...

Страница 9: ...Us FPGAs Adapter Card Configuration The adapter card has a DIP switch bank to control the main configuration of the card The DIP switch labeled SW1 can be found close to the upper edge of the board Th...

Страница 10: ...MXH94x MXH95x Transparent Adapter User s Guide Dolphin Interconnect Solutions Page 10 NOTE Please note that all cards utilizing 24 fiber MPO cannot be connected to cards utilizing 12 fiber MPO...

Страница 11: ...frequency clocking The card implements clock isolation Step 5 Installing and Removing Cables Installing and removing cables in NTB or Transparent Hot Add mode can be done while the systems are running...

Страница 12: ...ically be emailed to you if you follow the instructions found on the getting started document bundled with the adapter card If you fail to provide the correct serial number found on the getting starte...

Страница 13: ...shutdown Card will shut down on thermal overheat OFF 7 MCU Reset Holds the management processors in reset Board management is held in reset Normal operation OFF 8 Recover Enables the card to recover i...

Страница 14: ...rent Target DIP ON DIP switch view A Transparent Target One x16 upstream port L0 L1 L2 L3 One x16 downstream port OPT 1 OPT 2 Transparent Use Cases The transparent adapter card may be used as both a T...

Страница 15: ...target card Transparent Use Case B 1 Host Dual Expansion Configuration The host has an adapter card configured for Transparent Host operation and a direct x4 or x8 cable connection is used to connect...

Страница 16: ...serial number of the card i e MXH940 CC 012345 You can also get this information using lspci in Linux First identify the devices for the Dolphin Host card Then run lspci and identify the card It will...

Страница 17: ...roduction number 0x0000000A 0000010 in decimal Support More information about the product support and software downloads at http www dolphinics com mx Please email pci support dolphinics com if you ha...

Страница 18: ...Gen4 v1 and FireFly Gen3 PM40052 MXH94x BB MH95x BB Support for FireFly Gen3 and FireFly V2 PM40052 MXH94x CC MH95x CC Same Form Fit and Function as MXH94x BB MH95x BB optimized for volume manufacturi...

Страница 19: ...not ensure that it will comply with these standards in any random PC It is the responsibility of the integrator to ensure that their products are compliant with all regulations where their product wil...

Страница 20: ...ng or abnormal working conditions Damages which result from violating the specified operating or storage temperatures and airflow Damages caused by acts of nature e g floods storms fire or earthquakes...

Отзывы: