4.5 Electrical connection
4.5.1 mains operation
Use an authorised electrical professional for the
electric connections to ensure that the dispenser is
connected safety.
In rooms that contain showers and baths the unit
must not be mounted within the VDE regulation
defined safety areas (0.6m to the shower or bathtub
edge and 1.2m to shower heads). These paper roll
towel dispenser must be fixed out of reach of a
person using a bath or shower.
Connect the power supply directly to the designated
terminal.
Power supply: 1N AC 230 V 50 Hz
On the installation side is a pole disconnecting device
from the mains with a contact gap of minimum 3mm
per pole.
The power supply must be protected by a residual
current device (RCD).
Mains voltage and the voltage shown on the rating
plate must correspond.
In rare cases, a strong electromagnetic field may
occur in the range of 440kHz ±40kHz. This may
cause the sensor to activate and a delivery of paper.
To suppress this false triggering, reduce the sensor
range until the fault disappears.
User manual roll towel dispenser series DP 3107 / DP 3108 / DP 3109 / DP 3110 19