User Manual of DOLCWIUHFP
9
Figure2.4.1-1
2.4.2 Instruction
The instruction mentioned in the
Table 2.4.2-1
is based on the example showed on the
Figure
2.4.1-1
, if not suitable for your site, you can contact with Transmitter Solutions for assistance.
Tabel 2.4.2-1
Description
Overhead Installation
Install Height
Over 5.0 m (See the Left View of Overhead Installation in the
Figure 2.4.1-1)
Pole Type
L type as the Left View of Overhead Installation in the
Figure 2.4.1-1
)
Pole Position(H)
Over 0.25 m horizontal far from the edge of the lane (See Over View of Side
Installation in
Figure 2.4.1-1
Pole Position(V)
1.0 m far in vertical from the
Gate
Offset Angle with Pole
About 25
º
(see figure
2.4.1-1
)
Reader position (H)
The center of the Reader is 1.75 m far from the edge of the Lane in horizontal
2.4.3 Notice
1. If the DC Power is not waterproof, it is suggested to insert into the Ticket Box or be
covered.
2. The dia of the extension power wire should be 2.0 mm
"
if the length is over 10.0 m.