DB620 / DB 625
|
Dolphin
|
11
RESET BUTTON:
This function restores all the factory settings
except for the sensor range. If required, press the Reset button and
without releasing it, press the + button once.
SECURITY TIME:
The Security time, prevents continuous flushing
of water due to reflections or vandalism. By default, if the sensor is
covered for more than 90 seconds the water flow will shut
automatically. To resume regular operation any obstruction must
be removed. Press the SEC button. Wait until a quick flashing of
the LED of the sensor eye is perceived. Then, press + to increase
the security time and – to reduce it.
24 HOUR HYGIENE FLUSH:
This model includes a 24 hours
hygiene flush which is disabled. To activate the hygiene flush,
press the clock button. Wait until a quick flashing of the LED of the
sensor eye is perceived. Then press + to activate the hygiene flush.
To disable it PROX WAVE again, press – to deactivate it.
COMFORT FLUSH:
If your model includes a Comfort flush setting,
it can be activated by pressing the flush button. When the button
is pressed, one blink of the blue in the sensor eye is perceived. The
pre-programmed flush cycle will take place then. The Comfort flush
cannot be interrupted or deactivated by pressing any button until
it is over.
SETTINGS ADJUSTMENT