BC5083-120 User Manual
dolphinsolutions.co.uk
The upper cord pull should be located between
800mm & 1000mm above floor level.
The lower cord pull should be exactly 100mm above floor
level (remove excess cord)
The Over Door Indicator
provides an audibly and
visually signal to
indicate the area where
assistance is required.
VoCALL Unit
Ceiling Pull is surface mounted.
100
mm
K
n
o
t
the
c
o
rd
t
o
ensure
the
low
est
r
i
ng
i
s
100
mm
f
r
o
m
the
fl
oo
r
.
C
ut
off
e
x
cess
c
o
rd
.
Scre
w
the
t
wo
p
i
ece
c
o
nnct
o
r
t
o
gether
The Ceiling Pull should be
positioned so that its
readily assessable from
the WC, bath
(where applicable)
The Cancel Button
should be positioned so
that it is reachable from
the WC and a wheelchair.
I N STA L L AT I O N
› The Emergency Assist Alarm should be installed in accordance with the recommendations of BS8300 and to the
requirements of Building Regulations Approved Document M.
› The diagram below demonstrates a typical layout for installation in a disabled person toilet.
Note:
Where pertinent other or alternative standards of design and installation should be adhered to.
› All system components are designed to be sited internally and positioned in locations where they are readily
accessible by the user. The area should be clean and dry and sound and light levels allow the status of all device
indicators and sounders to be seen and heard.
› Any likelihood of tampering or vandalism should also be taken into account at time of design.
O P E R AT I O N
To Place a Call
Operate the Pull Cord. LED’s will illuminate on, Pull Cord Unit, Cancel Unit and Over Door
Indicator. An internal buzzer will also sound in the Over Door Indicator.
VoCALL Unit ...........
To Reset Call
Press the Cancel Button.
M A I N T E N A N C E
Weekly
Clean plates with a non abrasive cleaning cloth and detergent, do not use harsh or solvent
based cleaners.
Monthly
Test Call system by making and resetting a call.