The optimum sensing range is preset to 180 mm. If this needs to be adjusted please proceed as follows:
(And please also refer to TIMER ASSEMBLY DRAWING (-) as follows)
First of all, cut off the power supply, please.
Remove the ENCLOSURE / HOUSING of hand dryer.
Remove the outer case of TIMER ASSEMBLY.
Find the SENSING RANGE ADJUSTER inside the TIMER ASSEMBLY and
use tiny screw driver " - " type or " + " type to turn round the SENSING RANGE ADJUSTER:
(A) Clock--------------
Lengthen the sensing range (+)
(B) Counterclockwise-----
Shorten the sensing range (-)
Lengthen the sensing range (+)
Shorten the sensing range (-)