BC100SSC Replacement shock instructions for an installed unit:
1
Remove the inner changing station by removing the 6 white plastic caps. These caps will expose 6 spanner
screws that will need to be removed. Removing the screws will allow the inner unit to be detached from the
metal housing.
2
Locate the gas shock and inspect the brackets that the gas shocks are secured to in order to determine if
there is any damage to these brackets or the structure of the changing station.
3
If damage is present contact Dolphin for a replacement inner unit as fitting new struts to a damaged unit is not
safe
4
If no damage to the unit or basketry surrounding the shock is evident. using a flat head screwdriver, release
the “C” clip by sliding the screwdriver between the “C” clip and the head of the shock. Once released, pull the
head of the chock off the ball stud. Repeat this for the opposite end.
5
Take the new shock and attach the thin end to the ball stud closest to the hinge of the unit by pushing it onto
the ball stud.
6
Take the other end of the shock and compress until the head of the shock lines up with the ball stud. Push the
shock onto the ball stud until it clicks into place.
7
Open and close the inner changing unit to ensure that the shock is working properly.
8
Reattach the inner changing station using the 6 spanner screws from step 1 to the installed metal housing.
Once all the screws are secure, cover each screw with the white plastic caps.