Diagnostics  and  Remedies

I

f  the  dryer  will  not  run

The  dryer  cycles  by  itself
or  runs  constantly

The  dryer  runs  but  air
stream  is  low  pressure
and/or  low  velocity

Ensure  that  there  is  no  obstruction  on  or  in  front  of  the  IR  sensor.  Clean
any  dirt  or  debris  off  the  sensor  lens.  If  problem  persists,  replace  sensor.

First  ensure  that  the  breaker  supplying  the  dryer  is  operational.  If  it  is,
disconnect  the  power  and  remove  the  dryer  cover.  Taking  suitable
precautions  to  avoid  shock  hazard,  reconnect  the  power  and  check  for
Voltage  at  the  terminal  block.  Verify  that  connections  are  made  correctly.
Adjust  the  VR  to  make  sure  it  is  not  set  too  low.

Ensure  that  the  supply  Voltage  is  correct.    Dryer  will  run  weakly  if  the
input  Voltage  is  too  low.    Verify  Voltage  requirement  on  unit  rating  label
and  correct  supply  as  required.

The  dryer  makes  a  loud
noise  and  does  not  run
for  a  complete  cycle

Ensure  that  the  supply  Voltage  is  correct.  Dryer  will  make  a  loud  humming
noise  if  the  input  Voltage  is  too  high.  Verify  Voltage  requirement  on  unit
rating  label  and  correct  supply  as  required.  If  CBM  has  been  damaged,
replace  CBM,  IR  sensor  module  and  VR  component  and  cable.

Symptom                                                                                                                                 

Corrective  Actions  for  Initial  Installation  Failures

Symptom                                                                                                                                 

Corrective  Actions  for  In-Service  Failures

I

f  the  dryer  will  not  run

The  IR  sensor  only  “sees”
close  range  objects

The  dryer  only  blows  cold
air  during  a  full  cycle

Ensure  that  there  is  no  obstruction  on  or  in  front  of  the  IR  sensor.  Clean
any  dirt  or  debris  off  the  sensor  lens.  If  problem  persists,  replace  sensor.

First  ensure  that  the  breaker  supplying  the  dryer  is  operational.  If  it  is,
disconnect  the  power  and  remove  the  dryer  cover.  Replace  the  CBM
and  IR  sensor  module.  Test  the  VR  for  open  circuit  (see  Technical
Specifications  for  value).  Replace  VR  if  Ω  =  ∞.  Taking  suitable  precautions
to  avoid  shock  hazard,  reconnect  the  power  and  check  for  Voltage  at
the  terminal  block.

Disconnect  the  power.  Remove  the  dryer  cover  and  disassemble  the  blower-
motor/fan  housing.  Test  the  thermostat  for  open  circuit.  Check  the

 

heater

element  for  signs  of  burning  or  breakage.  Damaged  element  must

 

be  replaced.

The  heater  gets  hot  but
no  air  stream  is  produced

Disconnect  the  power.  Remove  the  dryer  cover  and  disassemble  the

 

blower-

motor/fan  housing.  Replace  the  fan  motor.

The  air  stream  is  low
pressure  and  velocity

Check  the  output  nozzle  for  obstructions.  If  none  are  present,  disconnect
the  power.  Remove  the  dryer  cover.    Remove  any  dust/lint  buildup
from  intake  vent  slots.  Disassemble  the  blower-motor/fan  housing.
Check  the  motor  brushes  for  worn  condition  (

  25/64"  [10  mm]  graphite

remains)  and  replace  them,  if  necessary.

Operating  Instructions  and  Parts  Manual 

Hand  Dryer

Semi-Recessed  High-Speed  hand  dr yer 

BC 2006 User Manual                                                                                                                                  www.dolphindispensers.co.uk

All manuals and user guides at all-guides.com

Содержание BC 2006

Страница 1: ...BC 2006 Dolphin Velocity Hand Dryer User Manual Please read carefully before use DOLPHIN All manuals and user guides at all guides com...

Страница 2: ...C WEEE NOTE This Product should not be disposed of with household waste Please recycle where facilities exist Check with your local authority for recycling advice Operating Instructions and Parts Manu...

Страница 3: ...ws Connections A Connect the live wire colored red or brown to the terminal block marked L B Connect the neutral wire colored black or blue to the terminal block marked N C Connect the ground wire col...

Страница 4: ...68 CFM 87 116 m h 15 16HP 350 700W 12000 18000 R R M Adjustable Brush Type Dual Ball Bearings Auto Resetting Thermostat turns unit off 120V at 275 F 135 C 240V at 221 F 95 C US Spec 240V at 221 F 105...

Страница 5: ...R sensor only sees close range objects The dryer only blows cold air during a full cycle Ensure that there is no obstruction on or in front of the IR sensor Clean any dirt or debris off the sensor len...

Страница 6: ...or Disconnect wires from the brush Using the screwdriver to take off the fixed screws from the brush motor for the two sides Replace with new brush and fasten the fixed screw then connect the wire on...

Страница 7: ...he screw of the cover and remove the cover 2 Adjust the heater switch on the PCB with a flathead screwdriver 2 1 Turn the switch to ON heater on 2 2 Turn the switch to 1 heater off Heater Element Swit...

Отзывы: