Dolgin TC200i Скачать руководство пользователя страница 3

 

 

 Dolgin Engineering 1019 Massachusetts Ave. Lexington, MA 02420 • (781) 863-1813 • www.dolgin.net  

 

90%) in about 2.5 hours. A 5600 mAh pack will take approximately 3.5 - 4 hours to charge.  Since a 

depleted battery pack absorbs charge current faster, than a partially charged one, most of the charge 

energy is absorbed during the initial stage of charging and then the rate of charge levels off towards 

the end.   

Charge channels  

Both charge channels are fully independent from each other; charge initiation and termination 

depend on a battery’s state of charge. An LCD display indicates each battery’s state of charge, in 

voltage, percent of readiness (estimated), and amount of charge in mAh input in it since the battery 

insertion.  

 
Test/Discharge circuit (optional) 

With the Test/Discharge circuit installed, the charger becomes a complete battery management 

system enabling battery characterization, as well as identifying anomalies resulting from aging and 

other deficiencies. 

The test performed is a full charge-discharge-full charge routine. This test will identify the true 

capacity of the battery displayed on the LCD panel. The discharge circuit closely approximates actual 

real life discharge, as seen by the battery in normal camera use.  
The circuit is associated with channel 1. 

 

Operation  

Charging 

Operation of the charger is fully automatic. Mount any battery to any open position on the charger 

and the charger will initiate the charge routine. While charging is in progress, the LCD display will 

indicate the battery voltage, estimated readiness in percent, and amount of charge accepted by the 

battery. Upon charge completion, the display will report the position number (1-2), amount of charge 

the battery has absorbed, and the completion message. 

Upon the battery insertion, the charger will identify the battery’s state of charge, and initiates the 

appropriate charge regimen. If the inserted battery is fully charged, it cannot safely absorb charge. 

The charger will display the “ # 1(2) Ready” message. 
 

Note: 

 

Estimated readiness is intended for the “charge in progress” status information. Accuracy may vary for an old 

or new battery, and between different sizes and makes. 

 

Amount of charge absorbed by the battery is displayed from the moment of insertion. If a fully depleted 
battery charged in full, the charge displayed is equal to the actual battery capacity in mAh. 

 

Upon the battery removal, please wait 2-3 seconds before inserting a new battery in the same position, as the 

charger channel needs this time to initialize. 

 

 

Status LEDs   

LEDs help to quickly identify charging state.  
1. Fast blink  

Battery is inserted; charge in progress 

2. On   

Battery is ready (charged over 90%) 

3. Slow blink   Test in progress 

 

Testing (optional feature) 

 

Insert the battery to be tested in position 1. 

 

Press “Test” button 

Отзывы: