24
UG 6960 / 05.12.17 en / 947
Safetyfunction: see below, Manual-Start (for automatic start make a bridge to ST2 instead of ON button).
Delay function: release delay (1)
K1/K2 instantaneous contact, K3/K4 delayed contact
DC24V
0V
A1+
A2
K8
K6
K7
K5
ST2
S21
13
47
23
57
+
+
24
58
38
68
14
48
M10780_b
K1
K3
K1
K3
K2
K4
K2
K4
UG6960
K5
K6
K7
K8
S22
S11
S12
Safetyfunction
ST1
On
Reset
RES
S22
S11
S12
M10757
Not-
Aus
S21
S21
S22
S11
S12
Schiebeschutztür
geschlossen
M10756
S1
S2
S22
S21
S11
S12
M10750
Fct.: E-stop (1),
with cross fault detection
SIL 3, PL e, Cat. 4
Fct.: Safety gate (2),
with cross fault detection
SIL 3, PL e, Cat. 4
Fct.: Two-hand control (3),
with cross fault detection
SIL 3, PL e, Cat. 4
Type III C to EN 574
S21
S22
S11
S12
Schaltleiste
M10754
S22
S11
S12
S12
S1
M11124
S21
S22
S11
S12
M10753
Not-
Aus
S21
Fct.: Safety mat / Safety edge (4),
with cross fault detection
SIL 3, PL e, Cat. 4
Fct.: Exclusive or contacts (5),
with cross fault detection
SIL 3, PL e, Kat. 4
Fct.: E-Stop (6),
without cross fault detection
SIL 3, PL e, Cat. 4
1)
S21
S22
S11
S12
Schiebeschutztür
geschlossen
M10752
OSSD1
OSSD2
S22
S21
S11 S12
Sender
Empfänger
DC 24V
0V
M10751
1)
To achieve the stated safety classification the
wiring has to be done with crossfault monitoring.
2)
To achieve the stated safety classification
light curtains with selftest (type 4) according
to IEC/EN 61496-1 have to be used.
Fct.: Safety gate (7),
without cross fault detection
SIL 3, PL e, Cat. 4
1)
Fct.: Light curtain (8),
without cross fault detection
SIL 3, PL e, Cat. 4
2)
Application Examples with safety function
Safetyfunction: see below, Manual-Start (for automatic start make a bridge to ST2 instead of ON button).
Delay function: release delay (1)
K1/K2 instantaneous contact, K3/K4 delayed contact
DC24V
0V
A1+
A2
K8
K6
K7
K5
ST2
S21
13
47
23
57
+
+
24
58
38
68
14
48
M10780_b
K1
K3
K1
K3
K2
K4
K2
K4
UG6960
K5
K6
K7
K8
S22
S11
S12
Safetyfunction
ST1
On
Reset
RES
S22
S11
S12
M10768
emergency
stop
S21
S21
S22
S11
S12
Sliding door
is closed
M10778
S1
S2
S22
S21
S11
S12
M10750
Fct.: E-stop (1),
with cross fault detection
SIL 3, PL e, Cat. 4
Fct.: Safety gate (2),
with cross fault detection
SIL 3, PL e, Cat. 4
Fct.: Two-hand control (3),
with cross fault detection
SIL 3, PL e, Cat. 4
Type III C to EN 574
S21
S22
S11
S12
safety edge
M10774
S22
S11
S12
S12
S1
M11124
S21
S22
S11
S12
M10772
emergency
stop
S21
Fct.: Safety mat / Safety edge (4),
with cross fault detection
SIL 3, PL e, Cat. 4
Fct.: Exclusive or contacts (5),
with cross fault detection
SIL 3, PL e, Kat. 4
Fct.: E-Stop (6),
without cross fault detection
SIL 3, PL e, Cat. 4
1)
S21
S22
S11
S12
Sliding door
is closed
M10770
OSSD1
OSSD2
S22
S21
S11 S12
Transmitter
Receiver
DC 24V
0V
M11317
+
+
1)
To achieve the stated safety classification the
wiring has to be done with crossfault monitoring.
2)
To achieve the stated safety classification
light curtains with selftest (type 4) according
to IEC/EN 61496-1 have to be used.
Fct.: Safety gate (7),
without cross fault detection
SIL 3, PL e, Cat. 4
1)
Fct.: Light curtain (8),
without cross fault detection
SIL 3, PL e, Cat. 4
2)
Application Examples with safety function
E. DOLD & SÖHNE KG • D-78114 Furtwangen
e-mail: [email protected] • internet: http://www.dold.com
•
PO Box 1251 • Telephone (+49) 77 23 / 654-0 • Telefax (+49) 77 23 / 654-356
Содержание SAFEMASTER C UG 6960
Страница 4: ...4 UG 6960 05 12 17 de 947...
Страница 16: ...16 UG 6960 05 12 17 en 947...
Страница 28: ...28 UG 6960 05 12 17 fr 947...