13
BN 5930.48/203, /204 / 22.01.19 en / xxxx
Your Advantages
• Can be used for long leads in the e-stop loop.
This allows a long distance between e-stop module and the e-stop button.
• Crossfault detection in the e-stop circuit
Features
•
According to
- Performance Level (PL) e and category 4 to EN ISO 13849-1
- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
- Safety Integrity Level (SIL) 3 to IEC/EN 61508
•
BN 5930.48/203 with cross fault detection by connecting
2 different phases, max. 400 V,
BN 5930.48/204 with cross fault detection by connecting
phase and neutral, max. 230 V
•
Dual voltage version
•
Emergency-stop circuit T12, T22:
optionally for AC 110 V / DC 60 V or AC 230 V / DC 110 V
•
Output: 3 NO, 1 NC contacts for AC 400 V
•
1-channel or 2-channel circuit
•
LED displays for channel 1, 2 and mains
•
Feedback circuit X1 - X2 for monitoring external contactors
•
Removable terminal strips
•
Width 100 mm
Protection of persons and machines
• Emergency stop circuits on machines
• Monitoring safety gates
LED power supply:
on when operating voltage present
LED K1:
on when supply on relay K1
LED K2:
on when supply on relay K2
0221559
41
42
K1
K2
K3
13 23 33
T11
T12
T33
T22
T34
X1
X2
X3
14 24 34
A1(+)
A2(-)
T33 T34
X1 X2
M7396_b
A1
(+)
T11 T12 T12 T22 13 23 33 41 X3
14 24 34 42
A2
(-)
41
42
K1
K2
K3
13
23
33
T11
T12
T33
T22
T34
X1
X2
S23
14
24
34
A1(+)
A2(-)
T33 T34
X1 X2
M7397_c
A1
(+)
T11 T12 T12 T22 13 23 33 41 S23
14 24 34 42
A2
(-)
BN 5930.48/203
BN 5930.48/204
One or more BN3081 extension modules or external contators with posi-
tively driven contacts can be used for contact multiplication of the emer-
gency stop module BN 5930.
Safety Technique
SAFEMASTER
Emergency Stop Module
BN 5930.48/203, BN 5930.48/204
Function Diagram
Circuit Diagrams
Approvals and Markings
Applications
Indicators
Notes
Connection Terminals
Terminal designation
Signal description
A1 (+)
+ / L
A2 (-)
- / N
T12, T22, X1, X2, X3, S23
Control inputs
T11, PE(-), T33, T34
Control outputs
13, 14, 23, 24, 33, 34
Forcibly guided NO contacts for
release circuit
41, 42
Forcibly guided indicator output
All technical data in this list relate to the state at the moment of edition. We reserve the right for
technical improvements and changes at any time.
Содержание SAFEMASTER BN 5930.48/203
Страница 4: ...4 BN 5930 48 203 204 22 01 19 de 106A...
Страница 12: ...12 BN 5930 48 203 204 22 01 19 en 106A...
Страница 20: ...20 BN 5930 48 203 204 22 01 19 fr 106A...