2-78
2.5.3.6
DA20 to CP200 Wiring Tables
Refer to the DA20 to CP200 wiring diagram fold-out, Figure 2.11.
Audio from DA20 to CP200
Audio from CP200 to DA20
DA20
CP Audio
Conn. J8
(DB25 Male)
Pin no.
CP200
JM21 (IDC 20 pin)
Pin no.
DA20
CP Audio
Conn. J7
DB25 Female
Pin no.
CP200
JM11 (IDC 20 pin)
Pin no.
1 AGND
1 GND
1 AGND
1 GND
2 Rs out
2 Q
2 Rs in
2 Q
3 AGND
3 blank
3 AGND
3 blank
4 AGND
4 blank
4 AGND
4 blank
5 AGND
5 blank
5 AGND
5 blank
6 AGND
6 blank
6 AGND
6 blank
7 AGND
7 blank
7 AGND
7 blank
8 AGND
8 blank
8 AGND
8 blank
9 AGND
9 blank
9 AGND
9 blank
10 AGND
10 blank
10 AGND
10 blank
11 AGND
not connected
11 AGND
not connected, cut short
12 AGND
not connected, cut short
12 AGND
not connected, cut short
13 AGND
not connected, cut short
13 AGND
not connected, cut short
14 L out
11 L
14 L in
11 L
15 Ls out
12 P
15 Ls in
12 P
16 Re out
13 Re
16 Re in
13 Re
17 R out
14 R
17 R in
14 R
18 Le out
15 Le
18 Le in
15 Le
19 n.c.
16 blank
19 n.c.
16 blank
20 C out
17 C
20 C in
17 C
21 S out
18 S
21 n.c
18 S
22 n.c.
19 blank
22 n.c.
19 blank
23 n.c.
20 blank
23 n.c.
20 blank
24 SW out
not connected to JM21, but
soldered to pin B1 of SK13
24 n.c.
not connected, cut short
25 Spare out
not connected, cut short
25 Spare in
not connected, cut short
CP200 to DA20 Sense/Control
The DA20 monitors the CP200 Future 8 and Future 11 control lines to determine which
format is selected on the CP200. A low level on Future 8 indicates that format 10 is
selected. A low level on Future 11 indicates that an optical film format is selected. Future
11 is used to cause the DA20 to assert format 10 automatically when the DA20 is in Auto
Digital Mode and valid digital audio is present. See the DA20 Users’ Manual for specific
information on the Auto Digital feature.
CTRL0 through CTRL7 are used to control and read status from the CP200 via the Cat.
No. 493 Auto Digital Adapter board. The DA20 is connected directly to the Cat. No. 493
adapter board using a 25 pin shielded cable. If no Cat. No. 493 is available, the DA20 and
CP200 can operate in non-auto digital mode by connecting the DA20 directly to the CP200
backplane. The signals required for basic operation of the DA20 and CP200 are listed in
the table below in bold type: