Figure 13: Laser Pointer Positioning During Horizontal Aiming
3. Tighten the M10 bolts to 4 Nm (2.95 ft-lb, 35.4 in-lb), so the horizontal adjustment is locked in place.
4. Loosen the M10 vertical angle adjustment points on the side of the CS128MH and tilt the cabinet to aim
the CS128MH toward the theater RLP. The angle adjustment range is +15/-15 degrees.
If a laser pointer is used to assist in the vertical aiming process:
a. Place the laser pointer on the top of the CS128MH enclosure.
b. Align the laser with the vertical plane of the enclosure.
c. Adjust the vertical angle of the CS128MH until the laser is directed at the RLP vertical plane.
Assembling the Dolby Speaker System 128