DOL 40R Series Скачать руководство пользователя страница 3

Technical User Guide

DOL 40R

www.dol-sensors.com

3

4 User Guide

Activated

Not active

Red

Green

Sensor

No time delay

Delayed

disconnection

Delayed

connection

Red

Red

Green

Green

DOL 41R

 has no time delay.

DOL 43R

 has an option for delayed disconnection. Time delay

starts When the activation stops (red flash) When this time stops,
the relay switches back.

DOL 45R

 has Apart from the settings mentioned above, also has

the option of delayed connection. The time delay starts when the
sensor is affected. When the delay period runs out, the relay will
switch. The relay does not switch back until the activation stops.

Sensitivity

Delayed disconnection Delayed connection

41R

43R

45R

DOL

The sensitivity and the delay length are adjusted by two switches. LEDs indicate when the switches are acti-
vated.

Green-0.2 mm

+0.2 mm

Sensitivity adjustment (DOL 41R / 43R / 45R)

press 1 x A+B simultaneously
press A or B for -0,2mm +0,2mm
DOL 41R settings is completed press A+B
DOL 43R and DOL 45R continue to the next setting by press A+B

Red

+1 sec.

+1 min

Time delay setting (DOL 43R/45R)

Press A or B for +1 1 seconds
Eksempel 1xA + 5xB = 65 seconds
DOL 43R settings is completed press A+B
DOL 45R continue to the next setting by press A+B

Yellow

On

Off

On / off delay (DOL 45R)

press A or B for delayed on or off
press A+B simultaneously = settings completed

Status

Red: sensor is affected
Green: sensor is unaffected
Yellow: Error
Flash: ​Time delay

Special functions

Factory setting: Hold A + B simultaneously for 15 seconds
Show delay Hold A + press 2xB (Red = 1 min. Green = 1 sek.)
Change delay: Hold A + press 4xB (+10 sec.) hold A + 5+B (÷5 sec.)
Hold A + 6+B (+1 hour.)
Switch off delay.: Hold A + press 7xB
switch off LED Hold A + 8xB
Switch on LED Hold A + 9xB

Содержание 40R Series

Страница 1: ...40R Capacitive Relay Sensor For other language variants of this document we refer to www dol sensors com or your local dealer dol sensors a s Agro Food Park 15 DK 8200 Aarhus N T 45 7217 5888 F 45 7217 5959 www dol sensors com ...

Страница 2: ...mounted so that at least 10 mm of the sensor end is free The DOL 40R series in a smooth design is mounted efficiently in a special gland additional accessory item number 140107 DOL 40R G The DOL 40R G series with M30 thread is mounted in a ø30 mm hole and is tightened with a locknut 3 Installation guide Installation servicing and troubleshooting of all electrical equipment must be carried out by q...

Страница 3: ...s indicate when the switches are acti vated Green 0 2 mm 0 2 mm Sensitivity adjustment DOL 41R 43R 45R press 1 x A B simultaneously press A or B for 0 2mm 0 2mm DOL 41R settings is completed press A B DOL 43R and DOL 45R continue to the next setting by press A B Red 1 sec 1 min Time delay setting DOL 43R 45R Press A or B for 1 minute 1 seconds Eksempel 1xA 5xB 65 seconds DOL 43R settings is comple...

Страница 4: ...e galvanically separated Test voltage 4 kV AC Specifications Variant understanding DOL 45R G T Thread Series Tube mount Distance of activation Adjustable 0 15 mm depending on material Factory setting is grain Time delay Adjustable 0 240 min Factory setting is 30 sec Mechanical Sensor length mm inches 110 4 5 16 Sensor diameter mm inches 30 1 3 16 Cable dimensions mm2 AWG 5x 0 75 5 x 18 Cable lengt...

Отзывы: