Technical User Guide
DOL 26SCR Serial
3
Adjustment
DOL 26 has trimmers with different functions depending on its type for adjustment.
4 Technical data
DOL 26SCR Serial
Electrical
Supply voltage (Ue)
V AC/DC
20 - 280
Frequency
Hz
47 - 63
Max. Current
mA AC/DC
500
Inrush current
A
˂ 2,5A @ 30 ms
Direct connection to Ue
(current >> 500 mA) with-
out damage to the sensor
times
˃10
Min. ON current
mA AC/DC
RMS
< 10 (Ue = 20 - 280)
OFF current
mA AC/DC
RMS
< 3 (Ue = 20 - 280)
Voltage drop, output ON
V AC/DC
˂ 6
Specifications
Detection speed
Hz
˂ 15
Time delay, start-up
ms
265
Time delay, ON*
s
˂ 0.065 - 600
Time delay, OFF* (ad-
justable)
s
0.1 - 600
Activation distance (Sn)*
(adjustable)
mm
(inches)
0 – 12 (0 – 0.47)
Safe activation distance
mm
(inches)
4 – 10 (0.16 – 0.39)
Repeatability
%
5
Hysteresis
%
4 - 10
MaxRunTimer* (3 set-
tings)
s
Off / Period 1 / Period 2
Number of single turn
240° potentiometer
0, 1 or 2
Number of outputs
1
Type of output
NO or NC
Indicator for sensor out-
put state ON or Error
Red LED
Mechanical
Sensor length
mm
(inches)
89 (3 1/2)
Sensor diameter (d)
mm
(inches)
18 (11/16)
Cable dimensions
mm2
(AWG)
2x0.5 (2xAWG20)