DOL 26SCR Series Скачать руководство пользователя страница 3

Technical User Guide

DOL 26SCR Serial

www.dol-sensors.com

3

Adjustment

DOL 26 has trimmers with different functions depending on its type for adjustment.

4 Technical data

DOL 26SCR Serial

Electrical

Supply voltage (Ue)

V AC/DC

20 - 280

Frequency

Hz

47 - 63

Max. Current

mA AC/DC

500

Inrush current

A

˂ 2,5A @ 30 ms

Direct connection to Ue
(current >> 500 mA) with-
out damage to the sensor

times

˃10

Min. ON current

mA AC/DC

RMS

< 10 (Ue = 20 - 280)

OFF current

mA AC/DC

RMS

< 3 (Ue = 20 - 280)

Voltage drop, output ON

V AC/DC

˂ 6

Specifications

Detection speed

Hz

˂ 15

Time delay, start-up

ms

265

Time delay, ON*

s

˂ 0.065 - 600

Time delay, OFF* (ad-
justable)

s

0.1 - 600

Activation distance (Sn)*
(adjustable)

mm

(inches)

0 – 12 (0 – 0.47)

Safe activation distance

mm

(inches)

4 – 10 (0.16 – 0.39)

Repeatability

%

5

Hysteresis

%

4 - 10

MaxRunTimer* (3 set-
tings)

s

Off / Period 1 / Period 2

Number of single turn
240° potentiometer

0, 1 or 2

Number of outputs

1

Type of output

NO or NC

Indicator for sensor out-
put state ON or Error

Red LED

Mechanical

Sensor length

mm

(inches)

89 (3 1/2)

Sensor diameter (d)

mm

(inches)

18 (11/16)

Cable dimensions

mm2

(AWG)

2x0.5 (2xAWG20)

Содержание 26SCR Series

Страница 1: ...6SCR Serial Capacitive sensor For other language variants of this document we refer to www dol sensors com or your local dealer dol sensors a s Agro Food Park 15 DK 8200 Aarhus N T 45 7217 5888 F 45 7217 5959 www dol sensors com ...

Страница 2: ...hin a PG 21 gland Threaded version mounted with M18 nut Mounting restrictions for non flush side sensi tive version 3 Installation guide Installation servicing and troubleshooting of all electrical equipment must be carried out by quali fied personnel in compliance with the applicable national and international standard EN 60204 1 and any other EU standards that are applicable in Europe DOL 26SCR ...

Страница 3: ...A AC DC RMS 3 Ue 20 280 Voltage drop output ON V AC DC 6 Specifications Detection speed Hz 15 Time delay start up ms 265 Time delay ON s 0 065 600 Time delay OFF ad justable s 0 1 600 Activation distance Sn adjustable mm inches 0 12 0 0 47 Safe activation distance mm inches 4 10 0 16 0 39 Repeatability 5 Hysteresis 4 10 MaxRunTimer 3 set tings s Off Period 1 Period 2 Number of single turn 240 pote...

Страница 4: ...rating temperature C F 20 to 70 4 to 158 Operating temperature USA and Canada le 300mA C F 20 to 70 4 to 158 Operating temperature USA and Canada le 500mA C F 20 to 65 4 to 149 Storage temperature C F 40 to 80 40 to 176 Protection class IP 69k DIN 40050 9 NEMA 1 3 4 6 12 13 Approval CE UL C UL Option can be changed introduced upon request See the current functions on the product label 604354 2022 ...