DOL 20SCR Скачать руководство пользователя страница 2

Technical User Guide

2

www.dol-sensors.com

DOL 20SCR

1 Product description

DOL 20SCR is a capacitive sensor for detection of loose and solid materials.

The sensor has a 2-wire connection (ON or OFF), which is protected against higher current (Ie) than specified,
incl. connection / short-circuit directly to supply voltage.

The product is suitable together with contactors, relays and similar within the agricultural and industrial sectors.
The mechanical design makes DOL 20SCRideal for integration into applications with limited space.

2 Mounting guide

Measurement through plastic material:

The sensor with mounting clip can be used for plastic types with
a minimum of moisture absorption.

Fit the sensor so that it is protected from the build-up of dust and
the impact of water on the detection area of the sensor, including
condensation.

If there is significant wear, the sensor should be mounted behind
a wear plate made of a suitable plastic material.

The sensor is not side sensitive, but to avoid incorrect detection
as a result of uncertainty with regard to mounting, it is best to
keep the sensor away from any metal components, see the di-
mensions in figure
(5 mm gap).

3 Installation guide

Installation, servicing and troubleshooting of all electrical equipment must be carried out by quali-
fied personnel in compliance with the applicable national and international standard EN 60204-1
and any other EU standards that are applicable in Europe.

The sensor must be connected as per the diagram

LED indication

Sensor status

LED OFF

Sensor is OFF

LED flashing

Sensor is OFF and ON delay is active

LED ON

Sensor is ON

If the max. current (Ie) is exceeded, the sensor will try to change from OFF to ON 6 times, at the same time as
quick pairwiseYellow LED flashes occur.

Содержание 20SCR

Страница 1: ...L 20SCR capacitive sensor For other language variants of this document we refer to www dol sensors com or your local dealer dol sensors a s Agro Food Park 15 DK 8200 Aarhus N T 45 7217 5888 F 45 7217 5959 www dol sensors com ...

Страница 2: ... detection area of the sensor including condensation If there is significant wear the sensor should be mounted behind a wear plate made of a suitable plastic material The sensor is not side sensitive but to avoid incorrect detection as a result of uncertainty with regard to mounting it is best to keep the sensor away from any metal components see the di mensions in figure 5 mm gap 3 Installation g...

Страница 3: ... the trimmer Sensitivity fixed distance or Distance can be adjusted on the trimmer MaxRun timer DOL 20SCR Settings on the trimmer Off Period 1 Period 2 5 Maintenance If the sensor is located in a particularly dirty environment it may be necessary to clean the area around the sensor Otherwise no additional maintenance is required 6 Technical data Electrical Rated voltage Ue V AC V DC 20 280 20 280 ...

Страница 4: ...ndicator for sensor ON Yellow LED Mechanical Cable length m ft 1 5 4 9 Cable dimensions mm AWG 2x0 5 2x20 Frame for mounting sensor Included Environment Temperature operation C F 20 70 4 158 Temperature operation US and Canada Ie 300 mA C F 20 70 4 158 Temperature storage C F 40 80 40 176 Protection class IP NEMA 69k 1 3 4 6 12 13 Approvals CE C UL UL Option can be changed introduced upon request ...

Отзывы: