1 Product description

DOL 114 is a high-precision humidity sensor for measuring relative humidity and temperature. It is intended for
application in livestock houses but is also well suited for a number of industrial applications.

The sensor features two analogue outputs with very low output resistances and full protection against short cir-
cuits and wiring failures.

The special sensor element and the built-in filter enable application in livestock houses with constantly high hu-
midity. The sensor ships with a built-in connector or cable, and with a specific adapted specification area - all
according to your needs.

The sensor is microprocessor-controlled and has a two-color light emitting diode (LED) to communicate the op-
eration status and the error diagnostic.

Sensor can be supplied with blinded LED for applications where this is needed.

2 Mounting guide

For optimum mounting of the sensor, use mounting clip or mount it free-hanging
in the cable.

The sensor element of the sensor requires free air passage.

Mount the sensor so it is not exposed to direct sunlight, as this would affect the
measurement.

 Remember to put on a protection cap before mounting the cable.

3 Installation guide

Installation, servicing and troubleshooting of all electrical equipment must be carried out by quali-
fied personnel in compliance with the applicable national and international standard EN 60204-1
and any other EU standards that are applicable in Europe.

3.1 Connection of the sensor

Supply voltage
11-30 V DC

+ V (Brown)

+ GND (Blue)

°C (Black)

% RH (White)

Signals and wire colors

Содержание 114 0-10 V

Страница 1: ...0 V Humidity and Temperature Sensor For other language variants of this document we refer to www dol sensors com or your local dealer dol sensors a s Agro Food Park 15 DK 8200 Aarhus N T 45 7217 5888 F 45 7217 5959 www dol sensors com ...

Страница 2: ...ontrolled and has a two color light emitting diode LED to communicate the op eration status and the error diagnostic Sensor can be supplied with blinded LED for applications where this is needed 2 Mounting guide For optimum mounting of the sensor use mounting clip or mount it free hanging in the cable The sensor element of the sensor requires free air passage Mount the sensor so it is not exposed ...

Страница 3: ...vely the sensor protective cap can be mounted The sensor must be placed with the tip pointing upwards during disinfection After the sensor has been exposed to water and condensation it requires a period where the relative humidity is lower than 80 RH in order for it to measure correctly Do not bend the sensor as this would inflict permanent damage on the electronics of the sensor 5 Technical data ...

Страница 4: ...ut current mA 20 Output impedance Ω 1 Mechanical Cable dimensions AWG 2 m 4 x 22 AWG 0 34 mm2 Max cable length m 200 m at 1 50 mm2 Environment Temperature operation C 0 C 60 C Temperature storage C 40 C 60 C Protection class IP 67 Shipment Packing dimensions H x W x D mm 275 200 20 Shipment weight ex connec tor g 150 5 1 Dimensions Dimensions in mm 154 107 5 4 603008 2022 11 18 en US Made in Denma...

Отзывы: