3

If the max. current (Ie) is exceeded, the sensor will try to change from OFF to ON 6 times, at the same time as
quick pairwisered LED flashes occur.

4 User Guide

When there is material in front of the sensor, the output is in the reference position (OFF). When the material
disappears, the timer, starts, and the output will change to on after the set delay.
The status of the sensor is indicated with a red LED.

The sensor sensitivity and delayed disconnection can be adjusted via the SmartAdjust app.

ON

OFF

Sensor

LED

Contact

ON

ON

OFF

OFF

Delayed disconnection:

fixed delay 

or

 delay can be adjusted via the SmartAd-

just app.

Delayed connection:

fixed delay 

or

 delay can be adjusted via the SmartAd-

just app.

Sensitivity:

fixed distance 

or

 distance can be adjusted via the

SmartAdjust app.

MaxRun-timer:

iDOL 20 SCR adjustable 1-7200s via SmartAdjust app

5 Maintenance

If the sensor is located in a particularly dirty environment, it may be necessary to clean the area around the
sensor.

Otherwise, no additional maintenance is required.

6 Technical data

Electrical

Rated voltage (Ue)

V AC

V DC

20 - 280
20 - 280

Frequency

Hz

47 - 63

Max. current (Ie)

mA

500

Direct connection to Ue (current >>
500 mA) without damage to the
sensor

Times

> 10

Min. ON current (Im)

mA RMS/DC

< 10 (Ue = 20 - 90)

mA RMS/DC

< 4 (Ue = 90 - 280)

OFF current (Ir)

mA RMS/DC

< 3 (Ue = 20 - 90)

mA RMS/DC

< 1 (Ue = 90 - 280)

Voltage drop (Out) (current > 20
mA)

mA

RMS/V DC

< 6

Time delay, start-up

ms

< 150

Time delay, ON (adjustable)

s

0 - 3600