EN – TECHNICAL USER GUIDE
INSTALLATION GUIDE
DOL 26SCR:
Connect the sensor in series with the load. The polarity is unimportant.
The sensor is protected against overload and short circuit. If the output current exceeds the nominal output current, the output function is switched
off. Eliminate the short circuit or choose a smaller load to eliminate the error. The current limitation error is indicated on the sensor by double
flashes followed by a pause.
DOL 26SCR
DOL 26PNP/NPN:
Connect the sensor to a DC supply and connect the loads between the outputs and V- for the PNP version and V+ for the NPN version.
The sensor is protected against polarity errors, and the outputs are protected against overload and short circuit. If the output current exceeds the
nominal output current, the output function is switched off. Eliminate the short circuit or choose a smaller load to eliminate the error. The current
limitation error is indicated on the sensor by double flashes followed by a pause.
DOL 26PNP
DOL 26NPN
LED INDICATION
LED indication
DOL 26SCR status
DOL 26PNP/NPN status
RED OFF
Sensor output is OFF
Sensor output is OFF
RED slow flashing
Sensor delay is active
Sensor delay is active
RED double flashing
Sensor load error (overcurrent protection is active)
MaxRunTimer is active (optional)
Sensor load error (overcurrent protection is active)
MaxRunTimer is active (optional)
RED ON
Sensor output is ON
Sensor output is ON
GREEN OFF
N.A.
No power to sensor
GREEN ON
N.A.
Power to sensor
ADJUSTMENT OF USER SETTINGS
The user settings can be adjusted by the single turn 240° trimmers – e.g. sensitivity and delay – see product label for details.
DA/EN/DE/ES - TEKNISK BRUGERVEJLEDNING
MAINTENANCE INSTRUCTIONS
o maintenance is required. However, it may be necessary to clean around the sensor, if it is located in a dirty environment.