background image

4

999239002 - 07/2018 

Original Operating Instructions 

Framax stripping corner I hydraulic

Assembly

Carefully lay the stripping cylinder on its side.

Remove Spring cotter 5mm and Connecting pin 

10cm.

Remove the adapter from the cylinder.

Remove both pins D17.5.

Push the adapter into the pushrod of the stripping 

corner and pin it into position with two pins D17.5.

Place the stripping cylinder on the centring stud of 

the stripping corner.

The centring studs must be seated in the recesses of 

the assembly plate.

Twist the stripping cylinder clockwise until fully 

engaged.

Push the locking pin into the hole in the stripping cor-

ner.

Note:

The locking pin acts as anti-twist lock for the stripping 

cylinder.

NOTICE

 ▪

Stripping cylinders must always be fully 

retracted for installation.

 ▪

It is not permissible to install the stripping 

cylinder on a stripping corner that does not 

have a hole for the locking pin!
This hole is a standard feature of all strip-

ping corners manufactured from 2005 

onward.

 ▪

To prevent abrasion or trapping damage, 

the hydraulic hoses must be secured to the 

neighbouring formwork panel and properly 

laid and arranged. Tight bending radii 

should be avoided.

A

Spring cotter 5mm

B

Connecting pin 10cm

C

Adapter for Framax stripping corner I

D

Pin D17.5

C

Adapter for Framax stripping corner I

D

Pin D17.5

E

Push-rod

F

Framax stripping corner I

9239-200-11

D

9239-208-01

A

B

C

9239-200-05

C

D

E

F

NOTICE

It is not permissible to install the adapter in the 

pushrod with only one pin D17.5

G

Framax stripping cylinder I

H

Centring studs of stripping corner

I

Assembly plate

G

Framax stripping cylinder I

H

Centring studs of stripping corner

J

Locking pin

9239-200-04

H

G

I

9239-200-03

G

H

9239-200-09

J

Содержание 588614000

Страница 1: ...0 Amstetten 999239002 07 2018 en GB The Formwork Experts Framax stripping corner I hydraulic 2017 models onward Original Operating Instructions Please retain for future reference by Doka GmbH A 3300 Amstetten 9239 200 01 ...

Страница 2: ...draulic unit SCP V1200 50 60Hz Follow the directions in the User Information booklet of the formwork system that is being used Designation Framax stripping corner I hydraulic Max cylinder force 10000 kg 22000 lbs Year of manufacture see rating plate 9239 214 01 A C B A Adapter for Framax stripping corner I B Connecting pin 10cm C Spring cotter 5mm D Pair of hydraulic hoses 4 0m pre mounted on Fram...

Страница 3: ...th Coupling adapter Framax stripping cylinder I intended use Boundary conditions for use Maintenance inspection Storage NOTICE Other use or use not in conformity with that stated above is non intended use and requires the prior written approval of the Doka company NOTICE The Framax stripping cylinder I is suitable for deployment at outside temperatures of between 5 C and 55 C Putting into service ...

Страница 4: ...ed for installation It is not permissible to install the stripping cylinder on a stripping corner that does not have a hole for the locking pin This hole is a standard feature of all strip ping corners manufactured from 2005 onward To prevent abrasion or trapping damage the hydraulic hoses must be secured to the neighbouring formwork panel and properly laid and arranged Tight bending radii should ...

Страница 5: ...necting pin 10cm 2 Back off the hexagon nut width across 41 mm by the desired difference 3 Extend the stripping cylinder until the Connecting pin 10cm can be reinstalled 4 Secure each Connecting pin 10 cm with a Spring cotter 5mm 5 Fully retract the stripping cylinder CAUTION Danger of crushing No body parts or objects between hydraulic cylinder and assembly plate A Spring cotter 5mm B Connecting ...

Страница 6: ...cm Retract the stripping cylinder Switch off the hydraulic unit and disconnect the hydraulic hoses Lift the stripping cylinder clear Remove the adapter Position pins D17 5 in the adapter holes Pin the adapter into the stripping cylinder with Con necting pin 10cm and secure with Spring cotter 5mm Erecting Stripping Retract Framax stripping cylinder I Extend Framax stripping cylinder I 9239 200 02 9...

Страница 7: ...Original Operating Instructions Framax stripping corner I hydraulic 7 999239002 07 2018 ...

Страница 8: ...e the pegging tube from the fixing unit Place the spindle tube on the centring stud of the stripping corner Twist the spindle tube clockwise until fully engaged Push the pegging tube over the thread of the spindle tube Insert Connecting pin 10cm through the pegging tube and the Adapter for Framax stripping corner I and secure with Spring cotter 5mm Tighten the spindle nut against the pegging tube ...

Страница 9: ...ramax stripping cylinder I Shown here with no guardrail system along the front Note Alternatively the shaft can be fitted with four Framax stripping cylinders I full complement A Framax stripping cylinder I B Framax stripping corner I C Hydraulic unit Framax V4 D Adapter for Framax stripping corner I C A D B B 9239 216 01 ...

Страница 10: ...d requires the prior written approval of the Doka company Doka accepts no liability for products that have been altered Repairs may be carried out only by Doka or specialist companies authorised by Doka To avoid damage the drive components must be stored in such a way that they are protected against direct climatic influences and aggressive substances The hydraulic unit Framax V4 must be inspected...

Страница 11: ...s Ensure scrupulous cleanliness during operation so that you can detect leaks at an early stage and rule out possible sources of errors Installation of the hydraulics Swivel the footplate flat to the ground Route the Pair of hydraulic hoses from the stripping cylinder to the Hydraulic unit Framax V4 and connect the hoses Temporarily stow pairs of hydraulic hoses that are not in use in the parking ...

Страница 12: ...aulic hoses for Framax stripping cylinder I D Pair of hydraulic hoses f stripp cyl 5 00m optional CAUTION Wrist injury After extending or retracting the stripping cylinder switch off the cordless screwdriver and disengage it from the drive A Cordless screwdriver 18 V 1800 rotation min B Bit width across 8 mm C Drive hexagon socket width across 8mm D Maximum oil level E Minimum oil level C D B 9239...

Страница 13: ...oss 17mm Refill the reservoir with approx 3 litres of hydraulic oil up to the maximum mark Use Shell Tellus S2 V15 hydraulic oil Re seal the oil filling opening Dispose of the waste oil and soiled cleaning utensils correctly Observe all relevant national laws Transport A Drive flap B Locking bore C Bit width across 8 mm D Locknut width across 12 mm painted red E Hexagon socket screw key width acro...

Страница 14: ...or the stripping cylinder to be operated with the Hydraulic unit Xclimb 60 V45 50 60Hz Required system pressure 200 bar Follow the directions in the Hydraulic unit Xclimb 60 V45 50 60Hz Operating Instruc tions 9 20 2873 0 02 C C B D NOTICE Invariably only one stripping cylinder can be connected to and operated with the Hydraulic unit Xclimb 60 V45 50 60Hz Exception No one in the danger zone Formwo...

Страница 15: ...he Hydraulic unit SCP V1200 50 60Hz A Flatface BG2 sleeve B Threaded coupling SKS BG3 connector C Threaded coupling SKS BG3 sleeve Follow the directions in the Hydraulic unit SCP V1200 50 60Hz Operating Instructions 92869 200 01 C D A B A C B NOTICE Invariably only one stripping cylinder can be operated with the Hydraulic unit SCP V1200 50 60Hz Exception No one in the danger zone Formwork erecting...

Страница 16: ... pertinent fundamental health and safety stipulations of the relevant EC Direc tives The following harmonised standards were applied EN ISO 12100 2010 EN 349 1993 A1 2008 EN 982 1996 A1 2008 Person authorised to compile technical documentation pursuant to European Directive on Machinery Annex II Dipl Ing Ludwig Pekarek Josef Umdasch Platz 1 A 3300 Amstetten Amstetten 14 06 2018 Doka GmbH Josef Umd...

Страница 17: ...amax V4 20 5 588981000 Hydraulikaggregat Framax V4 Hydraulic unit Xclimb 60 V45 50 60Hz 321 0 581322000 Hydraulikaggregat Xclimb 60 V45 50 60Hz System pressure controller Xclimb 60 V45 1 4 581329000 Systemdruckbegrenzer Xclimb 60 V45 Hydraulic unit SCP V1200 50 60Hz 2200 0 583102500 Hydraulikaggregat SCP V1200 50 60Hz Coupling adapter B Framax stripping cyl I 2 0 588982500 Kupplungsadapter B Frama...

Страница 18: ...nd distributing formwork technology for use in all fields of the construction sector With more than 160 sales and logistics facilities in over 70 countries the Doka Group has a highly efficient dis tribution network which ensures that equipment and technical support are provided swiftly and profession ally An enterprise forming part of the Umdasch Group the Doka Group employs a worldwide workforce...

Отзывы: