Doheny's 7816 Скачать руководство пользователя страница 5

10411 80th Avenue Pleasant Prairie, WI 53158 | Orders and Customer Care: 1-800-574-7665 | Fax: 1-800-323-5932 | Doheny.com 

CHAPTER 5

ELECTRICAL DATA

  Refer to information on motor nameplate for 

 

  electrical service data. All motors should have  

  fused disconnect switch or circuit breaker. Be sure  

  wire size is sufficient for pump HP and distance from  

 

power source. Wiring should be done in accordance  

  with applicable codes by a competent electrician.  

  We recommend the installation of a ground fault  

  circuit interrupter for maximum safety

CHAPTER 6

PUMP START UP

 

Gravity Fed Above Ground Pumps

  Do not operate pump until it has been primed as  

  water acts to cool and lubricate the seal. For pumps  

  without strainer bodies and located above water,  

  close  suction  line  valve  and  fill  pump  with  water  

  in order to prime. 

Self Priming Inground Pumps

  For pumps with strainer bodies and located above  

  water, prime by removing strainer cover and filling  

  strainer body with water. Pumps located below  

  water level will selfprime if all piping is also below  

  water level. After pump has been primed, energize  

  motor and open all suction and discharge line  

  valves. It may take some time for pump to remove  

  air from suction lines. If no flow is observed in five  

  minutes, stop the motor and re-prime. If the pump  

  fails to operate, check for air leaks. Refer to Trouble  

  Shooting section. After about ten minutes of 

 

  operation, check the return fittings for air bubbles.  

  A continuous flow of air indicates leaks in suction  

  line. Locate and correct any leaks immediately.

Controlling the Output

  Keep the gate valve in the suction line fully open  

  during operation. Should it be necessary to control  

  the output, use a valve in the return line

 Caution:

  Do not retighten strainer Ring-Lok during  

 operation.

 Caution:

  Do not operate pump with closed suction  

  or discharge valves.

CHAPTER 7

WINTERIZING

  Consult your dealer for advice on winterizing your  

  equipment  if  freezing  temperatures  occur  in  your  

  locality. His knowledge of your equipment makes  

  him the best qualified source of information. Follow  

  his recommendations, and if these include draining  

  the filter system, proceed as follows:

  1.  If your system does not contain a filter, proceed  

      to step 2.

      A.  For  sand  filters: 

BACKWASH

 for 3 to 5  

        minutes and set dial valve to 

WINTERIZE

.

      B.  For cartridge filters: Clean the filter element  

        and store in a dry place.

  2.  Drain system by loosening drain plugs (drain  

     plugs will drain without completely removing  

      the plug from unit) and/or removing pipe caps.

CHAPTER 8

WATER CHEMISTRY

  A proper and consistent use of chemicals is 

 

 

necessary to maintain clean, sanitary water, prevent  

  a spread of germ infection and control the growth of  

  algae which can spoil the appearance and 

 

  enjoyment of your pool or spa. Chlorine is the most  

  commonly used chemical to provide clean, sanitary  

  water. Either dry or liquid chlorine (calcium or  

  sodium hypochlorite) can be used which should be  

  added daily as it is dissipated by dirt, germs, sun  

  and wind. It is also important that the correct level  

  of acidity or alkalinity of the pool water be 

 

  maintained. This is the pH of your pool with pH 7.0  

  being neutral. Readings above 7.0 are alkaline and  

  below are acid. A desirable range is 7.2 – 7.4.

CHAPTER 9

PUMP MAINTENANCE

  1.  Motors  are  self-lubricating  –  no  lubrication  is  

     required.

  2.  Clean hair & lint strainer if you have a strainer  

      body pump.

  3.  Visually inspect motor for blockage of air vents  

     on motor shell. Remove any debris after 

 

      breaker off.

  4.  Shaft seals may become worn and must be  

      replaced if leakage is observed.

CHAPTER 10

CLEANING

 

Switch power off. Close valves in suction and return  

  line. Unscrew strainer Ring-Lok counterclockwise  

  and remove the strainer cover from hair and 

 

  lint strainer and lift out strainer basket. Clean and  

  replace the basket. Take care to seat basket 

 

  properly. Clean O-Ring and re-lubricate with a  

  non-pretroleum based lube, try Jack’s Magic Lube.  

  Clean  O-Ring  seats  on  cover  and  strainer.  Refit  

  cover and strainer – hand tighten only – and open  

  valves. Put pump back into operation. 

Caution: Do  

  not retighten strainer during operation.

CHAPTER 11

SERVICE & REPAIR PARTS

   Order all repair parts through your dealer. Give the  

  following information when ordering repair parts:

  1.  Unit nameplate data.

  2.  Description of part

Содержание 7816

Страница 1: ...ids warranty ATTENTION INSTALLER THIS MANUAL CONTAINS IMPORTANT INFORMATION ABOUT THE INSTALLATION OPERATION AND SAFE USE OF THIS PUMP THAT MUST BE PROVIDED TO THE END USER OF THIS PRODUCT FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS COULD RESULT IN SERIOUS INJURY This equipment must be installed and serviced by a qualified technician Improper installation can create electrical hazards which could ...

Страница 2: ...d pools and may also be used with hot tubs and spas if so marked Do not use with storable pools A permanently installed pool is constructed in or on the ground or in a building such that it cannot be readily disassembled for storage Astorable pool isconstructedsothatitmaybereadilydisassembled for storage and reassembled to its original integrity WARNING For hot tub and spa pumps 7 Do not install w...

Страница 3: ...mming Pools Wading Pools Spas and Hot Tubs and either i A safety vacuum release system SVRS meeting ASME ANSI A112 19 17 Manufactured Safety Vaccum Release SVRS for Residential and Commercial Swimming Pools Spa Hot Tub and Wading Pool Suction Systems and or ASTM F2387 Standard Specification for Manufactured Safety Vacuum Release Systems SVRS for Swimming pools Spas and Hot Tubs or ii A properly de...

Страница 4: ...on to 1 Drainage away from pump 2 Ventilation of pump motor 3 Access for future servicing and winterizing 4 Protection from the elements CHAPTER 3 GENERAL PLUMBING For Solvent Weld Connection Rigid or flexible PVC pipe can be used Pipe ends should be clean and free of any flash caused by the cutting operation Be sure that the proper adhesive is used on the type of pipe specified Note A primer will...

Страница 5: ...source of information Follow his recommendations and if these include draining the filter system proceed as follows 1 If your system does not contain a filter proceed to step 2 A For sand filters BACKWASH for 3 to 5 minutes and set dial valve to WINTERIZE B For cartridge filters Clean the filter element and store in a dry place 2 Drain system by loosening drain plugs drain plugs will drain without...

Страница 6: ...lter 7 Impeller clogged 8 Wrong rotation 3 phase only Low Pump Pressure 1 Pump running at reduced speed see above 2 Wrong rotation 3 phase only 3 Discharge valve or inlet fittings closed too much High Pump Pressure 1 Discharge valve or inlet fittings closed too much 2 Return lines too small 3 Dirty filters Noisy Pump and Motor 1 Plugged basket in skimmer or hair in lint strainer 2 Worn motor beari...

Страница 7: ...04080 Diffuser 2 7a 89106101 Impeller for 7816 1 7b 89106201 Impeller for 7817 1 8 65028026000 Seal Assembly 1 9 65431121080 O Ring 1 10 648910602080 Pump Cover 1 11 5225007000 Screw 3 8 16UNC 25 4mm 4 12 65244015000 Gasket M10 8 13 648910603080 Over Cover 1 14a 65023076000 1 0HP Motor for 7816 1 14b 65023077000 1 5HP Motor for 7817 1 15 5225008000 Screw 3 8 16UNC 50 8mm 4 16 647254205080 Supporti...

Страница 8: ...use or care shall be replaced at our option without charge within 90 days of the receipt of defective product barring unforeseen delays After 90 days to obtain warranty replacements defective components should be returned transportation paid to the place of purchase For further Doheny s service contact Doheny s cus tomer care department No returns may be made directly to the factory without the ex...