DRA

WING: Rough-in Dimensions

www.DOGIPOT.com        www.DOGIPARK.com

2100 Principal Row • Suite 405 • Orlando, Florida 32837

407.888.4627 • Fax: 407.888.8526 • 800.364.7681

Содержание DOGIFOUNTAIN 7751

Страница 1: ...to oper ate Push button shall be adjustable to ensure adequate flow without being wasteful 7751 DOGIPARK DOGIFOUN TAIN shall be lead free adhering to ANSI NSF 61 Section 9 ANSI A117 1 Standard Features Heavy duty Type 304 stainless steel 10 Schedule 10 main column and 7 GA flange High polished stainless steel bowl Solid stainless steel anti rotation bubbler Serviceable mesh strainer on inlet water...

Страница 2: ...uired Installation Supplies 5 Hardware Identification Chart 6 Installation Instructions Step 1 Fixture Installation 7 Step 2 Adjusting Drinking Spout Flow 8 Care and Maintenance 9 Troubleshooting 10 Detail Drawings General Dimensions 11 Exploded View w BOM 12 Rough in Dimensions 13 Freeze Resistant Valve Installation Detail 14 Warranty 15 Installation Operation Manual 7751 DOGIPARK DOGIFOUNTAIN PE...

Страница 3: ... DO NOT attempt to connect the valve assembly and spray head until after all flushing is complete and pure water is the only media that will be passing through the system Damage to the valve assembly or spray head caused by harsh chemicals or debris will not be covered by the manufacturer s warranty Any fittings provided by the installer should be made of plastic to electrically isolate the unit f...

Страница 4: ...OGIPARK dogifountain Installation Operation Manual 1 2018 Page 3 Physical Dimensions 7751 DOGIPARK DOGIFOUNTAIN www DOGIPOT com www DOGIPARK com 2100 Principal Row Suite 405 Orlando Florida 32837 407 888 4627 Fax 407 888 8526 800 364 7681 ...

Страница 5: ...OGIPARK dogifountain Installation Operation Manual 1 2018 Page 4 Rough In Dimensions 7751 DOGIPARK DOGIFOUNTAIN www DOGIPOT com www DOGIPARK com 2100 Principal Row Suite 405 Orlando Florida 32837 407 888 4627 Fax 407 888 8526 800 364 7681 ...

Страница 6: ...te outlet connections Gasket for waste outlet connection Shims for installation if necessary Supply piping Silicone caulk Plumbers putty WARNING DOGIPOT does not assume any responsibility for personal injury or damage to equipment due to improperly installed 7751 DOGIPARK DOGIFOUNTAIN www DOGIPOT com www DOGIPARK com 2100 Principal Row Suite 405 Orlando Florida 32837 407 888 4627 Fax 407 888 8526 ...

Страница 7: ...in 7751 DOGIPARK dogifountain Installation Operation Manual 1 2018 Page 6 Hardware Identification Chart www DOGIPOT com www DOGIPARK com 2100 Principal Row Suite 405 Orlando Florida 32837 407 888 4627 Fax 407 888 8526 800 364 7681 ...

Страница 8: ...ntain using 3 8 plastic tubing extra tubing not furnished Push tube straight into fitting on filter about 3 4 until it reaches a positive stop Water supply connection must comply with local codes 5 Connect fountain drain line to drainage system Drain is to be 1 1 2 IPS minimum to a porous gravel fill or main sewer line located below frost line Installer to provide waste trap downstream of drain co...

Страница 9: ...ox cover and push button together 3 Remove spring 4 Insert a standard flat head screwdriver into adjustment opening of valve as shown in Figure 4 5 Rotate screwdriver to adjust until desired flow is achieved a Rotate clockwise to increase flow b Rotate counterclockwise to decrease flow www DOGIPOT com www DOGIPARK com 2100 Principal Row Suite 405 Orlando Florida 32837 407 888 4627 Fax 407 888 8526...

Страница 10: ...member that fresh soft deposits of all kinds are relatively easy to remove while removing older hard deposits are much more difficult Establish as cleaning SCHEDULE Routine cleaning should involve ordinary soap or detergent and water applied with a sponge brush or cloth Baking soda borax or any of several non abrasive commercial cleansing agents can hasten the cleaning ac tion After scrubbing rins...

Страница 11: ...een damaged 3 The unit is rated for a maximum range of 30 105 psi C Inspect the unit s valve for damage and replace if necessary D Inspect the inline strainer for damage and or clogging and clean or replace as necessary E Check all fittings and tubing for damage and leaks Replace components as necessary II Unit has problems draining A Remove any debris from the drain B Remove any debris from the P...

Страница 12: ...ogifountain Installation Operation Manual 1 2018 Page 11 DRAWING General Dimensions www DOGIPOT com www DOGIPARK com 2100 Principal Row Suite 405 Orlando Florida 32837 407 888 4627 Fax 407 888 8526 800 364 7681 PRODUCT 7757 GREEN PRODUCT 7757 BLACK ...

Страница 13: ...stallation Operation Manual 1 2018 Page 12 DRAWING Exploded View w BOM 7751 Green 7751 Black note 1 4 TUBING NOT SHOWN IN EXPLODED VIEW www DOGIPOT com www DOGIPARK com 2100 Principal Row Suite 405 Orlando Florida 32837 407 888 4627 Fax 407 888 8526 800 364 7681 ...

Страница 14: ...in 7751 DOGIPARK dogifountain Installation Operation Manual 1 2018 Page 13 DRAWING Rough in Dimensions www DOGIPOT com www DOGIPARK com 2100 Principal Row Suite 405 Orlando Florida 32837 407 888 4627 Fax 407 888 8526 800 364 7681 ...

Страница 15: ... Valve Installation Detail NOTE SEE INDIVIDUAL DOCUMENTATION OF SPECIFIED 7751 FIXTURE FOR SPECIFIC MOUNTING DETAILS 7751 MOUNTING SHOWN FOR REFERENCE ONLY NOTE FRV 1 SINGLE VALVE RESISTANT SYSTEM SHOWN www DOGIPOT com www DOGIPARK com 2100 Principal Row Suite 405 Orlando Florida 32837 407 888 4627 Fax 407 888 8526 800 364 7681 ...

Страница 16: ...cturer s option transportation charges prepaid by the purchaser any component or part which upon our inspection shall be deemed as defective within the limita tions of this warranty The replacement or repair of defective units as stated in this warranty shall constitute the sole remedy of the purchaser and the sole liability of DOGIPOT DOGIPOT shall not otherwise be liable under any indirect damag...