5
MN1620
LUBRICATION
NOTE: Because reducer is shipped without oil, it is
necessary to add the proper amount of oil before operating
reducer. Use a high-grade petroleum base rust and oxidation
inhibited (R&O) gear oil – see tables. Follow instructions on
reducer warning tags, and in the installation manual.
Under average industrial operating conditions, the lubricant
should be changed every 2500 hours of operation or every 6
months, whichever occurs first. Drain reducer and flush with
kerosene, clean magnetic drain plug and refill to proper level with
new lubricant.
CAUTION: Too much oil will cause overheating and too little
will result in gear failure. Check oil level regularly. Failure to
observe this precaution could result in bodily injury.
Under extreme operating conditions, such as rapid rise and fall of
temperature, dust, dirt, chemical particles, chemical fumes, or oil
sump temperatures above 90°C, the oil should be changed every
1 to 3 months, depending on severity of conditions.
See Table 2–Oil Volumes for more information.
Table 2–Oil Volumes by Mounting Position
Case Size
Ratios
Oil Volume in Liters
Horizontal
Vertical
A (9:00)
B (6:00)
C (3:00)
D (12:00)
E (Up )
F (Down)
TA0107L
Single
0,6
0,5
0,6
1,3
1,2
1,4
Doubles
0,6
0,5
0,6
1,3
1,2
1,3
TA1107H
Single
1,3
0,7
0,6
1,6
1,4
1,8
Doubles
1,3
0,7
0,6
1,6
1,4
1,8
TA2115H
Single
2,0
1,2
1,0
2,5
2,2
2,9
Doubles
2,0
1,1
1,0
2,5
2,3
2,8
TA3203H
Single
2,7
1,6
1,7
3,9
3,1
4,2
Doubles
2,7
1,4
1,6
3,8
3,3
4,0
TA4207H
Single
4,2
2,5
2,8
7,0
6,0
7,3
Doubles
4,2
2,4
2,6
6,9
6,0
7,1
TA5215H
Single
7,0
4,7
5,5
12,5
11,0
12,4
Doubles
7,0
4,4
5,2
12,2
10,8
11,9
TA6307H
Single
8,3
5,5
6,2
15,3
12,5
15,3
Doubles
8,4
5,2
5,9
15,0
13,1
14,5
TA7315H
Single
8,0
11,1
13,2
21,3
20,9
23,7
Doubles
7,9
10,3
12,5
20,9
21,2
21,8
TA8407H
Doubles
7,3
11,1
12,9
23,8
22,7
24,4
TA9415H
Doubles
16,1
15,9
17,1
31,4
31,4
36,5
TA10507H
Doubles
36,0
26,1
24,4
50,6
50,9
53,0
TA12608H
Doubles
50,2
39,3
35,1
66,9
68,3
76,1
Notes:
1. Oil quantity is approximate. Service with lubricant until oil runs out of oil level hole.
2. Below 15 RPM output speed, oil level must be adjusted to reach the highest oil level plug. If reducer position is to vary from those shown in Figure 1, either more or
less oil may be required. Consult Dodge Product Support.
3. Refer to Figure 1 for mounting positions.
Содержание Ratios 15
Страница 31: ...31 MN1620...