Dodge FLEXIDYNE 70C Скачать руководство пользователя страница 8

World Headquarters

P.O. Box 2400, Fort Smith, AR 72902-2400 U.S.A., Ph: (1) 479.646.4711, Fax (1) 479.648.5792, International Fax (1) 479.648.5895 

Dodge Product Support

6040 Ponders Court, Greenville, SC 29615-4617 U.S.A., Ph: (1) 864.297.4800, Fax: (1) 864.281.2433

www.baldor.com

© Baldor Electric Company

MN4034  (Replaces 499868)

All Rights Reserved. Printed in USA.

10/11  Printshop  300

*4034-1011*

Flexidyne Mechanism Trouble Analysis

Symptom

Cause

Cure

Vibration

1.  Misalignment
2.  Bent shaft
3.  Excess flow charge
4.  Fused flow charge
5.  Improper installation – Output shaft 

jammed against housing

1.  Realign drive or coupling.
2.  Replace or straighten.
3.  Remove small amount of flow charge.
4.  Correct the overload.
5.  Readjust spacing between shafts and 

Flexidyne housing.

Erratic Acceleration

1.  Breakdown of flow charge
2.  Caked flow charge

3.  Below minimum amount of flow 

charge

1.  Replace flow charge.
2.  Moist environment – use stainless flow 

charge.

3.  Add flow charge.

Flexidyne Mechanism Doesn’t Slip

1.  Improper installation – Output shaft 

jammed against housing

2.  Flow charge in bearings – causing 

bearing seizure

1.  Readjust spacing between shafts and 

Flexidyne housing.

2.  Replace seals, bearings and 

flow charge or replace Flexidyne 
mechanism.

Excessive Slippage

1.  Not enough flow charge
2.  Overload
3.  Worn flow charge
4.  Worn rotor

1.  Add flow charge.
2.  Relieve overload
3.  Replace flow charge.
4.  Replace rotor.

Poor or short flow charge life

1.  Excessive slip at start up

2.  Excessive inching or jogging of 

machine

1.  Add flow charge to reduce starting 

time.

2.  Install time delay in motor control 

circuit.

Flexidyne Mechanism Flow Charge Analysis

Condition

Cause

1.  Red oxide color, granular consistency
2.  Red oxide color, powdery consistency, possibly with 

powdery flakes

3.  Black, powdery
4.  Red oxide, powdery and chunky
5.  Clumping of flow charge

1.  Normal after some usage.
2.  Worn-out, can cause Flexidyne mechanism damage.

3.  Rotor worn, excessive slip and heat.
4.  Worn-out and moisture present.
5.  Moisture present, use stainless flow charge.

Содержание FLEXIDYNE 70C

Страница 1: ...ing without slip and with 100 efficiency Consequently the motor accelerates instantly to base speed while the load starts gradually and smoothly Housing Flow Charge Output Shaft Rotor Flexible Couplin...

Страница 2: ...will be observed with greater amounts of flow charge The FLEXIDYNE mechanism should start the load smoothly and without delay provided the proper amount of flow charge has been used Should the accele...

Страница 3: ...e housing cavity before the unit locks in Any acceleration time between the minimum and maximum listed is acceptable although a shorter acceleration time will generally provide longer wear life For ap...

Страница 4: ...s Oz Lbs Oz 1 70C 70D 1 0 1 10 500 1 2 1 12 400 1 5 1 14 33 1 1 2 70C 70D 1 5 1 13 300 1 9 2 1 260 2 2 2 3 210 2 75C 75D 2 0 1 10 250 2 5 1 13 190 3 0 2 0 150 3 75C 75D 3 0 1 15 150 3 7 2 3 125 4 5 2...

Страница 5: ...36 2 5 143 140 88 85 49 45 33 29 3 0 133 120 80 74 45 39 28 25 4 0 90 83 60 54 36 30 23 19 6 0 60 38 21 13 8 0 41 29 16 10 10 0 36 23 13 8 Starting HP Maximum Allowable Acceleration Time in Seconds Fo...

Страница 6: ...and needle bearing inner race 7 Remove the six drive hub screws and remove the drive hub housing Remove housing seal 8 Remove rotor retainer and seal felt 9 Remove ball bearing snap ring and remove b...

Страница 7: ...1 305138 411296 419007 407082 305018 419190 305091 305138 411296 419007 407082 305018 419190 305091 305138 411296 419007 407082 305018 419190 305091 305138 411296 419007 407082 305018 419190 30 32 34...

Страница 8: ...tainless flow charge 3 Add flow charge Flexidyne Mechanism Doesn t Slip 1 Improper installation Output shaft jammed against housing 2 Flow charge in bearings causing bearing seizure 1 Readjust spacing...