5
Reinstalling the Outlet–
Install the AC/USB charging outlet in the receptacle
box before plugging in the Docking Drawer.
•Afterthereceptacleboxhasbeencorrectlyinstalledinthe
backofthedrawerand(ifapplicable)allwirescorrectly
reattached,theAC/USBchargingoutletcanbeinstalled.
REMINDER: IF THE CABLE ARM GROUND WIRE WAS REMOVED DURING
INSTALLATION, MAKE SURE IT HAS BEEN REATTACHED AND TORQUED
PROPERLY. MAKE SURE THE CIRCUIT BREAKER IS WIRED IN SERIES WITH
THE LINE (BLACK) WIRE AS SHOWN IN THE WIRING DIAGRAM.
• FollowtheAC/USBchargingoutletinstructions(includedinoutletpackaging)
andconnecttheblack,white,andgreenwiresinaccordancewiththose
instructions.
Specifications–
DockingDrawer
™
TechnicalSpecifications:
• ACPower:125V,tamperresistantNEMA5-15Rduplexreceptacle.
• DC(USB)Power:5.2V,12.5WduplexUSBchargingreceptaclewith
integratedon/offsafetyswitch.
• Maxratedcurrent@125VAC:3A.Circuitisprotectedby5Apopout
breakeraccessiblefromtheuserside.Designedforchargingpersonal
electronicdevicesonly.
Operation–
• InstructionsspecifictotheUSBchargingoutletare
includedwiththeoutletitself.
• TheDockingDrawerincludesa5Aresettablecircuit
breaker.Breakertripisindicatedbythewhitebutton
protrudingapproximately3/8”outfromthehousing.
Toreset,correctthesourceofovercurrentandpush
thewhitebuttonbackin.
Wiring Diagrams–
Receptacle Box Wiring
Green Wire (ground):
green screw
White Wire (neutral):
silver screw
Black Wire (line):
brass screw