DNF CONTROLS LIMITED WARRANTY 

 
DNF  Controls  warrants  its  product  to  be  free  from  defects  in  material  and 
workmanship  for  a  period  of  one  (1)  year  from  the  date  of  sale  to  the  original 
purchaser from DNF Controls. 
 
In  order  to  enforce  the  rights  under  this  warranty,  the  customer  must  first  contact 
DNF’s  Customer  Support  Department  to  afford  the  opportunity  of  identifying  and 
fixing the problem without sending the unit in for repair.  If DNF’s Customer Support 
Department  cannot  fix  the  problem,  the  customer  will  be  issued  a  Returned 
Merchandise Authorization number (RMA).  The customer will then ship the defective 
product  prepaid  to  DNF  Controls  with  the  RMA  number  clearly  indicated  on  the 
customer’s shipping document.  The merchandise is to be shipped to: 
 
DNF Controls 
12843 Foothill Blvd., Suite C 
Sylmar, CA  91342 
USA 
 
Failure  to  obtain  a  proper  RMA  number  prior  to  returning  the  product  may  result in 
the return not being accepted, or in a charge for the required repair. 
 
DNF Controls, at its option, will repair or replace the defective unit.  DNF Controls will 
return the unit prepaid to the customer.  The method of shipment is at the discretion 
of  DNF  Controls,  principally  UPS  Ground  for  shipments  within  the  United  States  of 
America.    Shipments  to  international  customers  will  be  sent  via  air.    Should  a 
customer  require  the  product  to  be  returned  in  a  more  expeditious  manner,  the 
return shipment will be billed to their freight account. 
 
This  warranty  will  be  considered  null  and  void  if  accident,  misuse,  abuse,  improper 
line  voltage,  fire,  water,  lightning,  or  other  acts  of  God  damaged  the  product.    All 
repair  parts  are  to  be  supplied  by  DNF  Controls,  either  directly  or  through  its 
authorized dealer network.  Similarly, any repair work not performed by either DNF 
Controls or its authorized dealer may void the warranty. 
 
After  the  warranty  period  has  expired,  DNF  Controls  offers  repair  services.  
Equipment  is  evaluated  and  repair  price  quoted  prior  to  any  work  performed.    DNF 
Controls  reserves  the  right  to  refuse  repair  of  any  unit  outside  the  warranty  period 
that is deemed non-repairable. 
 
DNF Controls shall not be liable for direct, indirect, incidental, consequential or other 
types of damage resulting from the use of the product. 
 

# # # 

 
 

USO 

RESTRITO

Содержание SW2X1-GPI

Страница 1: ...1 of 15 12843 Foothill Blvd Suite C Sylmar California 91342 V 818 898 3380 F 818 898 3360 sales dnfcontrols com Model No SW2X1 GPI SWITCHER RS422 SWITCHER USER MANUAL Rev 1 2 For Use with Rev 2 0 Hard...

Страница 2: ...1 RS422 6 6 MODE SELECTION SW2X1 GPI 7 a MODE 1 7 b MODE 2 7 7 MODE SELECTION SW2X1 RS422 LOCAL REMOTE CONTROL 8 a MODE 1 8 b MODE 2 8 8 MODE SELECTION SW2X1 RS422 2X1 1X2 MODE 9 a MODE 1 9 b MODE 2 9...

Страница 3: ...Original manual 081707 Rev 1 01 Added GPI wet dry jumper description 102411 Rev 1 1 Added 1x2 mode for SW2X1 RS422 082312 Rev 1 2 Added polarity indicators to RS422 pin outs 061113 Rev 1 3 Revised we...

Страница 4: ...ystem to backup system at the press of a button In the event of power failure on board bypass relays switches A input to output 2 INSTALLATION SW2X1 GPI a Chose whether the GPI will be self powered or...

Страница 5: ...ector d Connect the destination GPI connections to the Output connector e Connect the power supply s connector 9 pin female D into the housing s POWER connector male 9 pin D The PWR LED on front panel...

Страница 6: ...er 2 in the same manner to INPUT B c Connect an RS422 serially controlled VTR using an RS422 9 pin D type male to male cable into the 9 pin female connector labeled OUTPUT d Connect the power supply s...

Страница 7: ...ng the jumper after power up will have no effect Power MUST be turned off then on to change the SW2X1 s MODE Jumper Diagram for Mode 1 b MODE 2 Remote control ONLY is possible Local control is disable...

Страница 8: ...R UP Changing the jumper after power up will have no effect Power MUST be turned off then on to change the SW2X1 s MODE Jumper Diagram for Mode 1 b MODE 2 Remote control ONLY is possible Local control...

Страница 9: ...mined ONLY at POWER UP Changing the jumper after power up will have no effect Power MUST be turned off then on to change the SW2X1 s MODE Jumper Diagram for Mode 1 b MODE 2 The unit operates in 1 in 2...

Страница 10: ...press the red ENABLE switch simultaneously with a black SELECT switch A or B The selected input s status indicator will light c Setting the LOCKOUT switch to ON to the left side will disable the front...

Страница 11: ...External select A Active low opto isolated internally 2 External select B Active low opto isolated internally 3 n c 4 n c 5 LED B external drive B input status indicator 6 GROUND 7 GROUND 8 n c 9 LED...

Страница 12: ...GPI OUTPUT CONNECTOR 9 Pin D Type Female D9F Pin Description Pin Description 1 GPO 1 N O 6 GPO 1 COM 2 GPO 2 N O 7 GPO 2 COM 3 GPO 3 N O 8 GPO 3 COM 4 GPO 4 N O 9 GPO 4 COM 5 Ground C SW2X1 RS422 RS42...

Страница 13: ...SW2X1 User Manual 13 of 15 11 FRONT REAR VIEW a FRONT VIEW SW2X1 GPI b FRONT VIEW SW2X1 RS422 c REAR VIEW SW2X1 USO RESTRITO...

Страница 14: ...pair or replace the defective unit DNF Controls will return the unit prepaid to the customer The method of shipment is at the discretion of DNF Controls principally UPS Ground for shipments within the...

Отзывы: