DNF Controls SW2X1-GPI Скачать руководство пользователя страница 1

 

SW2X1 User Manual

 

 

1 of 15

 

 
 
 

                       12843 Foothill Blvd. Suite C 
                     Sylmar, California 91342 
                   V: 818.898.3380 
                 F: 818.898.3360 
               [email protected] 

 
 
 
 
 
 
 
 
 
 

 

 

Model No.  SW2X1  

-GPI SWITCHER 

-RS422 SWITCHER 

 
 

 

 
 
 
 

USER MANUAL 

 

Rev. 1.2 

 

For Use with Rev 2.0 Hardware 

 

 
 

USO 

RESTRITO

Содержание SW2X1-GPI

Страница 1: ...1 of 15 12843 Foothill Blvd Suite C Sylmar California 91342 V 818 898 3380 F 818 898 3360 sales dnfcontrols com Model No SW2X1 GPI SWITCHER RS422 SWITCHER USER MANUAL Rev 1 2 For Use with Rev 2 0 Hard...

Страница 2: ...1 RS422 6 6 MODE SELECTION SW2X1 GPI 7 a MODE 1 7 b MODE 2 7 7 MODE SELECTION SW2X1 RS422 LOCAL REMOTE CONTROL 8 a MODE 1 8 b MODE 2 8 8 MODE SELECTION SW2X1 RS422 2X1 1X2 MODE 9 a MODE 1 9 b MODE 2 9...

Страница 3: ...Original manual 081707 Rev 1 01 Added GPI wet dry jumper description 102411 Rev 1 1 Added 1x2 mode for SW2X1 RS422 082312 Rev 1 2 Added polarity indicators to RS422 pin outs 061113 Rev 1 3 Revised we...

Страница 4: ...ystem to backup system at the press of a button In the event of power failure on board bypass relays switches A input to output 2 INSTALLATION SW2X1 GPI a Chose whether the GPI will be self powered or...

Страница 5: ...ector d Connect the destination GPI connections to the Output connector e Connect the power supply s connector 9 pin female D into the housing s POWER connector male 9 pin D The PWR LED on front panel...

Страница 6: ...er 2 in the same manner to INPUT B c Connect an RS422 serially controlled VTR using an RS422 9 pin D type male to male cable into the 9 pin female connector labeled OUTPUT d Connect the power supply s...

Страница 7: ...ng the jumper after power up will have no effect Power MUST be turned off then on to change the SW2X1 s MODE Jumper Diagram for Mode 1 b MODE 2 Remote control ONLY is possible Local control is disable...

Страница 8: ...R UP Changing the jumper after power up will have no effect Power MUST be turned off then on to change the SW2X1 s MODE Jumper Diagram for Mode 1 b MODE 2 Remote control ONLY is possible Local control...

Страница 9: ...mined ONLY at POWER UP Changing the jumper after power up will have no effect Power MUST be turned off then on to change the SW2X1 s MODE Jumper Diagram for Mode 1 b MODE 2 The unit operates in 1 in 2...

Страница 10: ...press the red ENABLE switch simultaneously with a black SELECT switch A or B The selected input s status indicator will light c Setting the LOCKOUT switch to ON to the left side will disable the front...

Страница 11: ...External select A Active low opto isolated internally 2 External select B Active low opto isolated internally 3 n c 4 n c 5 LED B external drive B input status indicator 6 GROUND 7 GROUND 8 n c 9 LED...

Страница 12: ...GPI OUTPUT CONNECTOR 9 Pin D Type Female D9F Pin Description Pin Description 1 GPO 1 N O 6 GPO 1 COM 2 GPO 2 N O 7 GPO 2 COM 3 GPO 3 N O 8 GPO 3 COM 4 GPO 4 N O 9 GPO 4 COM 5 Ground C SW2X1 RS422 RS42...

Страница 13: ...SW2X1 User Manual 13 of 15 11 FRONT REAR VIEW a FRONT VIEW SW2X1 GPI b FRONT VIEW SW2X1 RS422 c REAR VIEW SW2X1 USO RESTRITO...

Страница 14: ...pair or replace the defective unit DNF Controls will return the unit prepaid to the customer The method of shipment is at the discretion of DNF Controls principally UPS Ground for shipments within the...

Отзывы: