Dnake AC-Y4 Скачать руководство пользователя страница 2

 

Remark 

Please follow the user manual for correct installation and testing. 
It’s recommended to test the terminal after powering on for 15 
minutes. The terminal is for indoor installation only. If there is any 
doubt please call our tech-supporting and customer center. 

Our company applies ourselves to reformation and innovation of 
our products. No extra notice for any change. The illustration 
shown here is only for reference. If there is any difference, please 
take the actual product as the standard. 

The product and batteries must be handled separately from 
household waste. When the product reaches the end of service life 
and needs to be discarded, please contact the local administrative 
department and put it in the designated collection points in order to 
avoid the damage to the environment and human health caused by 
any disposal. We suggest recycling and reusing the material 
resources. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Содержание AC-Y4

Страница 1: ...Y4 is an information technology equipment rather than medical facility Temperature measurement is only an auxiliary function and cannot be used as medical diagnosis basis USER MANUAL Wrist Temperature...

Страница 2: ...extra notice for any change The illustration shown here is only for reference If there is any difference please take the actual product as the standard The product and batteries must be handled separ...

Страница 3: ...1 2 5cm to measure the temperature 1 If the temperature is normal device will have a voice prompt Normal Temperature and the screen will display as below picture At the same time the door can be open...

Страница 4: ...conds the screen will back to main page 2 If temperature is abnormal device will have an alarm voice and prompt Normal Temperature and the screen will display as below picture After 3 seconds the scre...

Страница 5: ...b Settings Web Settings If you want to configure advance settings please login webpage of AC Y4 The default IP address of AC Y4 is 192 168 68 90 please change IP network segment the same as AC Y4 on y...

Страница 6: ...put unlock signal Normal Device will output unlock signal when the temperature is normal Both Device will output unlock signal when the temperature is normal or abnormal Temperature Type Celsius Devic...

Страница 7: ...thresholds according to different environment 3 Network Settings You can change the network settings in Network page 4 Other Settings You can reboot the device by clicking Reboot button and reset fac...

Страница 8: ...details 2 Interface Description Please refer to the real object for details 1 Interface of Y4 Terminal Brown SEN _INPUT White Brown RS485 White Blue ALARM_IN Blue RS485 Black GND White Green WG_0UT_D1...

Страница 9: ...2 0 USB interface Internet port Access network Power input 12V 12V power input Wiegand input 1 White Black WG_IN_D0 Wiegand input Alarm output 2 White Purple LOCK_NC Alarm output door lock signal norm...

Страница 10: ...nd output 7 White Green WG_OUT_D1 Wiegand output GND 8 Black GND GND GND 9 Black GND GND GND 10 Black GND GND RS485 11 Blue RS485 RS485 Alarm input 12 White Blue ALARMJN Alarm input RS485 13 White Bro...

Страница 11: ...wer cord with wet hands or unplug the power source by pulling the power supply Do not bend or damage the power cord Do not touch the equipment with wet hands Do not let the power slide or cause a coll...