background image

 

DMX-Universal-Demux

 

 

Operation mode 

 

The operation mode is selectable via a jumper. It is important to place the jumper in 
accordance to the following drawings to ensure a clean function.  
 
It is not possible to combine the modes.  
 
 

With switch 10 the output signal can be inverted in any operating mode. 

 
 
 

 Hysteresis 127/128 

(no jumper placed)

 

 
In threshold mode (hysteresis 127/128) 8 successive 
DMX channels are received.  
The belonging output will be set on OFF if the 
received value is between 0 and 127 and set on ON 
if the received value is between 128 and 255. 
Thereby output 1 is according to the first and output 8 is according to the last 
channel.  
 
 
This mode allows switching external load relays. 
The following picture shows the connection:  
 
 
 

V

+

G

N

D

G

N

D

G

N

D

O

U

T

1

G

N

D

D

M

X

-

D

M

X

+

O

U

T

2

O

U

T

3

O

U

T

4

O

U

T

5

O

U

T

6

O

U

T

7

O

U

T

8

 

 
 
 
 
 
 
 

J1

J2

J3

J4

J5

 

Содержание DMX-Universal-Demux

Страница 1: ...DMX Universal Demux User Manual...

Страница 2: ...from 12V up to 24V Different operation modes By jumper the operating mode of the DMX Universal Demux can be selected Available are the operation modes Threshold Bin r PWM Servo Strobo Controllable via...

Страница 3: ...thout load Protocol DMX512 RDM DMX channels 1 or 8 channels depends on selected mode Output 8 open collector outputs max 500mA DMX FAIL HOLD 0 100 Operation mode Threshold switches at 50 Binary 8 Bit...

Страница 4: ...DMX Universal Demux 4 Connection...

Страница 5: ...ultifunctional display In the normal operation mode the LED lights non stop In this case the device is working If the LED is permanently dark there is no DMX512 input signal Furthermore the LED signal...

Страница 6: ...s 127 128 no jumper placed In threshold mode hysteresis 127 128 8 successive DMX channels are received The belonging output will be set on OFF if the received value is between 0 and 127 and set on ON...

Страница 7: ...ON 11011011B Output 5 OFF 01001101B Output 5 ON 11011011B Output 6 OFF 01001101B Output 6 OFF 11011011B Output 7 ON 01001101B Output 7 ON 11011011B Output 8 OFF 01001101B Output 8 ON 11011011B Strobe...

Страница 8: ...he PWM Frequency is ca 175 Hz Servo Control only jumper J4 is placed The DMX Universal Demux receives 8 successive DMX Channels and outputted a signal for triggering customary servos Thereby each outp...

Страница 9: ...second as soon as the DMX value is 170 or higher After that the DMX value must fall below 85 again to trigger a switching pulse again DMX channel DMX value Function 1 8 0 170 Output OFF 171 255 Output...

Страница 10: ...be set to OFF A DMX start address set by the address switches is always prior This device supports the following RDM commands Parameter ID Discovery Command SET Command GET Command ANSI PID DISC_UNIQU...

Страница 11: ...device serial number GET Send PDL 0 Receive PDL 21 21 Byte ASCII Text IDENTIFY_MODE PID 0xD402 Stellt den Mode ein der mit IDENTIFY_DEVICE ausgef hrt wird GET Send PDL 0 Receive PDL 1 1 Byte IDENTIFY_...

Страница 12: ...ct power supply Set DIP switch 1 up to 10 to ON Turn on device connect power supply The LED lights up 20x during ca 3 seconds While the LED lights up set DIP switch 10 to OFF Now the Factory Reset is...

Страница 13: ...DMX Universal Demux 13 Dimensions All details in mm...

Страница 14: ...DMX Universal Demux 14 Equipment Top hat rail housing 700 Power supply 12V...

Страница 15: ...the EMC directive 2014 30 EU is necessary Disposal Electronical and electronic products must not be disposed in domestic waste Dispose the product at the end of its service life in accordance with ap...

Страница 16: ...he board must be connected and adjusted to foreign components according to the device paperwork This work can only be done by qualified personnel which read the full device paperwork and understand it...

Страница 17: ...ems All information contained in this manual was arranged with largest care and after best knowledge Nevertheless errors are to be excluded not completely For this reason I see myself compelled to poi...

Отзывы: