DMX-Universal-Demux
6
Operation mode
The operation mode is selectable via a jumper. It is important to place the jumper in
accordance to the following drawings to ensure a clean function.
It is not possible to combine the modes.
With switch 10 the output signal can be inverted in any operating mode.
Hysteresis 127/128
(no jumper placed)
In threshold mode (hysteresis 127/128) 8 successive
DMX channels are received.
The belonging output will be set on OFF if the
received value is between 0 and 127 and set on ON
if the received value is between 128 and 255.
Thereby output 1 is according to the first and output 8 is according to the last
channel.
This mode allows switching external load relays.
The following picture shows the connection:
V
+
G
N
D
G
N
D
G
N
D
O
U
T
1
G
N
D
D
M
X
-
D
M
X
+
O
U
T
2
O
U
T
3
O
U
T
4
O
U
T
5
O
U
T
6
O
U
T
7
O
U
T
8
J1
J2
J3
J4
J5
Содержание DMX-Universal-Demux
Страница 1: ...DMX Universal Demux User Manual...
Страница 4: ...DMX Universal Demux 4 Connection...
Страница 13: ...DMX Universal Demux 13 Dimensions All details in mm...