background image

 

DMX-Splitter 4

 

7   

 

 

Accessories 

 

Top hat rail mounting 700 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

Power supply 12V 

 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

Содержание DMX-Splitter 4

Страница 1: ...DMX Splitter 4 User Manual ...

Страница 2: ...ur own safety please read this user manual and warnings carefully before installation Contents Description 3 Data Sheet 4 Content 4 LED Display 4 Connection 5 Dimensions 6 Accessories 7 CE Conformity 8 Disposal 8 Risk Notes 9 ...

Страница 3: ... provides these at four galvanically isolated outputs Extremely light construction Extremely light DC DC converters are used for galvanic isolation Power supply via one power supply unit The power supply occurs via one power supply unit The voltage range is between 8V up to 24V Compact design for top hat rail mounting The DMX Splitter 4 is suitable for installation in top hat rail mountings with a...

Страница 4: ...els galvanically isolated Connections Screw terminals Dimensions 64 2mm x 82mm Content 1x DMX Splitter 4 1x Quick manual german and english LED Display LED green The green LED lights up as soon as operation voltage is connected LED yellow The yellow LED lights up as soon as a DMX signal is connected to DMX IN ...

Страница 5: ...plitter 4 GND V GND DMX DMX DMX GND GND DMX DMX GND DMX DMX GND DMX DMX DMX DMX GND DMX DMX IN DMX OUT 1 DMX OUT 2 DMX OUT 3 DMX OUT 4 POWER 12 24V If more than 4 DMX Outputs are needed several DMX Splitter 4 can be combined as follows ...

Страница 6: ...DMX Splitter 4 6 Dimensions All details in mm ...

Страница 7: ...DMX Splitter 4 7 Accessories Top hat rail mounting 700 Power supply 12V ...

Страница 8: ...he EMC directive 2014 30 EU is necessary Disposal Electronical and electronic products must not be disposed in domestic waste Dispose the product at the end of its service life in accordance with applicable legal regulations Information on this can be obtained from your local waste disposal company Warning This device is no toy Keep out of the reach of children Parents are liable for consequential...

Страница 9: ... board must be connected and adjusted to foreign components according to the device paperwork This work can only be done by qualified personnel which read the full device paperwork and understand it Operating risk The Change or the operation under special conditions of the installed systems components could as well as hidden defects cause to breakdown within the running time Misusage risk Any nons...

Страница 10: ...ad using electronic systems All information contained in this manual was arranged with largest care and after best knowledge Nevertheless errors are to be excluded not completely It is pointed out that neither a guarantee nor the legal responsibility or any liability for consequences which are due to incorrect information is assumed This document does not contain assured characteristics The guidan...