DMX-LED-Dimmer X9HR+
25
Set dimming curve via USB
To transfer the Look-Up Table to the
DMX-LED-Dimmer X9HR
a PC-Connection
cable and a USB-Connection at the PC is necessary.
Via the software DMX-Configurator the LookUp-Tables can be defined. The DMX-
Configurator is available for free as download.
- Connect the DMX-LED-Dimmer X9HR with a
standard USB-Mini-B connection cable to PC. As
shown in the picture on the right site, plug the
cable on the USB-Connection of the DMX-LED-
Dimmer X9HR.
- Install the USB-Driver if it is not available.
- Start the DMX-Configurator Software
(V2.3.9 or higher is needed)
- Generate a connection to DMX-LED-Dimmer X9HR
- Open Hardware-Settings (menu
Hardware
Hardware Settings
)
For each output (OUT1-OUT9) a table with DMX-Values in the range of 0-
255 and the according output values (OUTPUT) is available.
A graphic presentation illustrates the output line.
- Configure the output curve
- Check the output curve by selecting the LookUp
Test
and move the slider.
The connected LED behaves according to the output line.
- Select
WRITE TO DEVICE
to transfer the table to the DMX-LED-Dimmer
X9HR.